Installation
41
CV17 17" Modero Coor Video Touch Panels
12.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly before finalizing the installation.
13.
Disconnect the terminal end of the power cable from the power supply.
14.
Follow the procedures outlined within the
Step 1: Removing the existing NXD Outer Housing
section on
page 18 to carefully reinstall the LCD panel back into the back box housing.
15.
Carefully slide the main unit into the cutout until the Mounting Tabs of the NXD-CV17 unit lie flush
against the wall.
16.
Insert and secure the four #6 screws into their corresponding holes located along the sides of the NXD-
CV17 (using a grounded Phillips-head screwdriver) until the unit is secure and flush against the wall.
17.
Reinstall the magnetic faceplate (
A
in
FIG. 41) back onto the main NXD unit. Make sure to align the
Microphone, Light, and PIR Motion sensor locations to their respective openings on the front bezel/
faceplate.
18.
Connect the terminal RJ-45, Ethernet, and any optional audio/video wiring to their respective terminal
locations on either the NXA-AVB Breakout Box, Ethernet port, or NetLinx Master.
19.
Reconnect the terminal power connector on the PSN and apply power.
Installing an NXD into an (optional) Rack Mount Kit (NXA-RK17)
1.
Remove the magnetic faceplate/bezel from the main NXD unit by gripping the faceplate and pulling with
gentle outward force.
2.
Thread the incoming RJ-45, Ethernet, and any optional audio/video wiring (from their terminal locations)
through the opening in the equipment rack. Refer to the
Wiring Guidelines for the 17" Panels
section on
page 43 for pinout descriptions. Leave enough slack to accommodate any re-positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding locations along the side of the (un-
powered) NXD touch panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin
power connector.
4.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly to prevent repetition of the
installation.
5.
Disconnect the terminal end of the power cable from the connected power supply.
6.
Insert the main 17-inch Modero unit into the NXA-RK17 (FIG. 42).
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the equipment rack.
Содержание modero NXD-CV17
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV17 17 Modero Touch Panel Last Revised 8 04 2010...
Страница 10: ...viii CV17 17 Modero Coor Video Touch Panels Table of Contents...
Страница 56: ...Installation 46 CV17 17 Modero Coor Video Touch Panels...
Страница 86: ...Upgrading Modero Firmware 76 CV17 17 Modero Coor Video Touch Panels...
Страница 162: ...Appendix 152 CV17 17 Modero Coor Video Touch Panels...
Страница 167: ...Troubleshooting 157 CV17 17 Modero Coor Video Touch Panels...