Appendix
150
CV17 17" Modero Coor Video Touch Panels
When working with ranges specified by the [] mask, the keyboard allows you to enter a number between
the values listed in the ranges. If a user enters a value that is larger than the max, the maximum number
of right-most characters is used to create a new, acceptable value.
Example 1
: If you type "125" into a field accepting 0-100, then the values displayed will be
"1", "12", "25".
Example2
: If the max for the filed was 20, then the values displayed will
be "1", "12", "5".
When data overflows from a numerical field, the overflow value is added to the previous field on the
chain,
if
the overflow character was specified. In the above example, if the overflow flag was set, the first
example will place the "1" into the previous logical field and the second example will place "12" in the
previous logical field. If the overflow filed already contains a value, the new value will be inserted to the
right of the current characters and the overflow field will be evaluated. Overflow continues to work until
a filed with no overflow value is set or there are no more fields left (i.e. reached first field).
If a character is typed and that characters appear in the Next Field list, the keyboard should move the
focus to the next field. For example, when entering time, a
":"
is used as a next field character. If you hit
"1:2", the 1 is entered in the current field (hours) and then the focus is moved to the next field and 2 is
entered in that field.
When entering time in a 12-hour format, entry of AM and PM is required. Instead of adding
AM/PM to the input mask specification, the AM/PM should be handled within the NetLinx code. This
allows a programmer to show/hide and provide discrete feedback for AM and PM.
Input mask output examples
The following are some common input masking examples:
URL resources
A URL can be broken into several parts. For example: the URL
http://www.amx.com/company-info-
home.asp
. This URL indicates that the protocol in use is
http
(HyperText Transport Protocol) and that
the information resides on a host machine named
www.amx.com
. The image on that host machine is
given an assignment (
by the program
) name of
company-info-home.asp
(Active Server Page)
.
The exact meaning of this name on the host machine is both protocol dependent and host dependent. The
information normally resides in a file, but it could be generated dynamically. This component of the
URL is called the file component, even though the information is not necessarily in a file.
A URL can optionally specify a port, which is the port number to which the TCP connection is made on
the remote host machine. If the port is not specified, the default port for the protocol is used instead. For
example, the default port for http is 80. An alternative port could be specified as: http://
www.amx.com:8080/company-info-home.asp.
Output Examples
Common Name
Input Mask
Input
IP Address Quad
[0|255]{.}
Any value from 0 to 255
Hour
[1|12]{:}
Any value from 1 to 12
Minute/Second
[0|59]{:}
Any value from 0 to 59
Frames
[0|29]{:}
Any value from 0 to 29
Phone Numbers
(999) 000-0000
(555) 555-5555
Zip Code
00000-9999
75082-4567
Содержание modero NXD-CV17
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV17 17 Modero Touch Panel Last Revised 8 04 2010...
Страница 10: ...viii CV17 17 Modero Coor Video Touch Panels Table of Contents...
Страница 56: ...Installation 46 CV17 17 Modero Coor Video Touch Panels...
Страница 86: ...Upgrading Modero Firmware 76 CV17 17 Modero Coor Video Touch Panels...
Страница 162: ...Appendix 152 CV17 17 Modero Coor Video Touch Panels...