Troubleshooting
154
CV17 17" Modero Coor Video Touch Panels
Troubleshooting Information (Cont.)
Symptom
Solution
My NXT-BP battery pack is
blinking when I check the battery
life indicator.
• A blinking battery life LED indicates that there is less than 10% power
charge remaining on the battery.
• It is recommended that you fully charge the battery either in the
NXA-BASE/B battery base or in the NXT-CHG battery charger.
• Refer to the
NXA-BASE/B Battery Base Kit (FG2255K)
section on
page 21 for more information.
I was using the power from PSN,
and when I connected my
NXA-BASE/B battery base to the
active panel, my screen went
blank.
• Modero battery bases can not be "hot-swapped" or replaced without
powering down the Modero and removing the PSN connector.
If you are currently using a direct power connection to the panel and
then wish to connect an NXA-BASE/B.
First, power-down the panel and detach the rear power connection.
Then, remove any batteries from within the NXA-BASE/B and
connect the battery base to the underside of the panel.
After connecting the base to the un-powered panel, then run power
to the panel by either reconnecting the power cable to the rear of
the panel or inserting the NXT-BP batteries into the NXA-BASE/B.
• Refer to the
NXA-BASE/B Battery Base Kit (FG2255K)
section on
page 21 and
Installing the NXA-BASE/B to an NXT Modero
Panel
section on page 22 for more information.
I can’t seem to completely charge
my batteries from within an
NXA-BASE/B connected to a
power supply.
NXT-BP batteries can be charged from either an external NXT-CHG
battery charger or from within the NXA-BASE/B located below an NXT
panel.
• The NXA-BASE/B Battery base should be updated with the latest
firmware (part of the Modero firmware KIT file) from
www.amx.com
.
• The base can only charge batteries while the NXT panel is in Sleep
Mode. If the panel parameters are set to their highest values, the
priority for the power draw becomes the active panel functions and
no power is routed to the base for charging.
• Adjust the Display Timeout value to allow the panel to commence the
Sleep Mode and begin charging batteries within the base (drawing
power from a PSN).
• Refer to the
NXA-BASE/B Battery Base Kit (FG2255K)
section on
page 21 for more information.
My WEP doesn’t seem to be
working.
• WEP will not work unless the same default key is set on both the
panel and the AP.
• For example: if you had your access point set to default key 4 which
was 01:02:03:04:05 and you set the Modero to key 1 which was also
01:02:03:04:05 it will not work. You have to set key 4 on the Modero
to 01:02:03:04:0.
NetLinx Studio only detects one of
my connected Masters.
Each Master is give a Device Address of 00000.
• Only one Master can be assigned to a particular System number. If
you want to work with multiple Masters, open different instances of
NetLinx Studio and assign each Master its own System value.
• Example: a site has an NXC-ME260/64 and an NI-4000. In order to
work with both units. The ME260/64 can be assigned System #1 and
the NI-4000 can then be assigned System #2 using two open
sessions of NetLinx Studio 2.4.
Содержание modero NXD-CV17
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV17 17 Modero Touch Panel Last Revised 8 04 2010...
Страница 10: ...viii CV17 17 Modero Coor Video Touch Panels Table of Contents...
Страница 56: ...Installation 46 CV17 17 Modero Coor Video Touch Panels...
Страница 86: ...Upgrading Modero Firmware 76 CV17 17 Modero Coor Video Touch Panels...
Страница 162: ...Appendix 152 CV17 17 Modero Coor Video Touch Panels...
Страница 167: ...Troubleshooting 157 CV17 17 Modero Coor Video Touch Panels...