Configuring Communication
63
CV17 17" Modero Coor Video Touch Panels
Master Connection section - NetLinx Master Ethernet IP Address - URL Mode
In this mode, enter the System Number (zero for an unknown System Number) and the IP/URL of the Master
(Master Port Number is defaulted to
1319
).
1.
Press the
ICSNET/Ethernet
field (
from the Master Connection section
) until the choices cycle to the
word
Ethernet
. Refer to the
System Connection Page
section on page 99 for more information about the
fields on this page.
2.
Press the
Mode
field until the choices cycle to the word
URL
.
By selecting
URL
, the System Number field becomes read-only (grey) because the panel pulls this
value directly from the communicating target Master (virtual or not). A virtual Master system value
can be set within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.
3.
Press the
Master IP/URL
field to open a Keyboard and enter the Master IP Address
(obtained from the
Diagnostics - Networking Address dialog
of the NetLinx Studio application)
.
4.
Click
Done
to accept the new value and return to the System Configuration page.
5.
Do not alter the Master Port Number value (
this is the default value used by NetLinx
).
6.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
7.
Press the
Back
button to open the Protected Setup page.
8.
Press the on-screen
Reboot
button to both save any changes and restart the panel.
Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode
In this mode, you must add the Modero panel IP Address into the URL List of the Master (using NetLinx
Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from
its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP Address
from the IP Settings of the System Connection page.
The
DHCP/Static
field (in the IP Settings section of the System Connection page) must be set to
DHCP
to get Dynamic IP information for the panel.
Press the on-screen
Reboot
(from the Protected Setup page) to both save any changes and restart
the panel.
After power-up, press the grey Front Setup Access button for
3 seconds
to access the Setup page.
Navigate to the
Setup > Protected Setup > System Connection
page and note the newly obtained
Dynamic IP Address information from the IP Settings section. This information is then entered into
the URL List for the connected NetLinx Master.
2.
Toggle the
ICSNET/Ethernet
field until
Ethernet
is selected (
from the Master Connection section of the
System Connection page
).
3.
Press the
Mode
field (to set the connection Mode) until the choices cycle to the word
Listen
.
4.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
5.
Select the
OnLine Tree
tab from the Workspace window.
6.
Select
Diagnostics
>
URL Listing
from the Main menu (FIG. 60).
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number (from
within the Device Addressing dialog) is correctly assigned.
Содержание modero NXD-CV17
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV17 17 Modero Touch Panel Last Revised 8 04 2010...
Страница 10: ...viii CV17 17 Modero Coor Video Touch Panels Table of Contents...
Страница 56: ...Installation 46 CV17 17 Modero Coor Video Touch Panels...
Страница 86: ...Upgrading Modero Firmware 76 CV17 17 Modero Coor Video Touch Panels...
Страница 162: ...Appendix 152 CV17 17 Modero Coor Video Touch Panels...
Страница 167: ...Troubleshooting 157 CV17 17 Modero Coor Video Touch Panels...