Configuring Communication
65
CV17 17" Modero Coor Video Touch Panels
Using G4 Web Control
®
to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4 enabled panel via the web. This
feature works in tandem with the new browser-capable NetLinx Security firmware update (
build 300 or
higher
). G4 Web Control is only available with the latest Modero panel firmware.
Refer to the
G4 Web Control Page
section on page 90 for more detailed field information.
1.
Press the grey Front Setup Access button for
3 seconds
to open the Setup page.
2.
Press the
Protected Setup
button (located on the lower-left of the panel page) to open the Protected Setup
page and display an on-screen keypad.
3.
Enter
1988
into the Keypad’s password field (
1988 is the default password
).
4.
Press
Done
when finished.
5.
Press the
G4 Web Control
button to open the G4 Web Control page (FIG. 61).
6.
Press the
Enable/Enabled
button until it toggles to
Enabled
(
light blue color
).
7.
The
Network Interface Select
field is read-only and displays the method of communication to the web.
Verify you have selected the proper interface connection as this field does not auto-detect the
connection type being used (
see below
)
.
Wired
is used when a direct Ethernet connection is being used for communication to the web.
This
is the default setting if either no wireless interface card is detected or if both an Ethernet and
wireless card connection is detected by the panel.
Wireless
is used when a wireless card is detected within the internal card slot. This method
provides an indirect communication to the web via a pre-configured Wireless Access Point.
8.
Press the
Web Control Name
field to open the Web Name keyboard.
9.
From the Web Name keyboard, enter a unique alpha-numeric string to identify this panel. This
information is used by the NetLinx Security Web Server to display on-screen links to the panel.
The on-
screen links use the IP Address of the panel and not the name for communication
(FIG. 62).
Verify your NetLinx Master (ME260 or NI-Series) has been installed with the latest
firmware KIT file from
www.amx.com
. Refer to your NetLinx Master Instruction
Manual for more detailed information on the use of the new web-based NetLinx
Security.
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
FIG. 61
G4 Web Control page
Содержание modero NXD-CV17
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV17 17 Modero Touch Panel Last Revised 8 04 2010...
Страница 10: ...viii CV17 17 Modero Coor Video Touch Panels Table of Contents...
Страница 56: ...Installation 46 CV17 17 Modero Coor Video Touch Panels...
Страница 86: ...Upgrading Modero Firmware 76 CV17 17 Modero Coor Video Touch Panels...
Страница 162: ...Appendix 152 CV17 17 Modero Coor Video Touch Panels...
Страница 167: ...Troubleshooting 157 CV17 17 Modero Coor Video Touch Panels...