Serial Communications
|
A-11
3Ah/058d
Reserved
N/A
3Bh/059d
Reserved
N/A
3Ch/060d
Reserved
N/A
3Dh/061d
Reserved
N/A
3Eh/062d
Reserved
N/A
3Fh/063d
Reserved
N/A
40h/064d
Reserved
N/A
41h/065d
Reserved
N/A
42h/066d
Reserved
N/A
43h/067d
Reserved
N/A
44h/068d
Reserved
N/A
45h/069d
Cal_h10
Auto calibration time 10 hour value
Read and Write
46h/070d
Cal_h1
Auto calibration 1 hour value
Read and Write
47h/071d
Cal_m10
Auto calibration 10 minute value
Read and Write
48h/072d
Cal_m1
Auto calibration 1 minute value
Read and Write
49h/073d
Ver_h10
Auto verify time 10 hour value
Read and Write
4Ah/074d
Ver_h1
Auto verify time 1 hour value
Read and Write
4Bh/075d
Ver_m10
Auto verify time 10 minute value
Read and Write
4Ch/076d
Ver_m1
Auto verify time 1 minute value
Read and Write
4Dh/077d
Dry_Press
Dry Process pressure, entered by the user
Read and Write
4Eh/078d
Optemp
The cell temperature setpoint
Read and Write
4Fh/079d
Reserved
N/A
50h/080d
Cool_flags
Flag used for internal/external cooler control
Read only
51h/081d
Cool_SP
External cooler set point
Read and Write
52h/082d
Moist_Bias
The moisture bias set point
Read and Write
53h/083d
Reserved
N/A
54h/084d
Reserved
N/A
55h/085d
Reserved
N/A
56h/086d
Dry_AT
Dry Cell slope
Read only
57h/087d
Dry_AT_ratio
Dry Cell slope used during last calibration
Read only
58h/088d
Dry_Tc_ratio
Cell/thermocouple compensation multiplier
Read only
59h/089d
Reserved
N/A
5Ah/090d
Reserved
N/A
5Bh/091d
Calcycle
Interval between auto cals [1 hour to 90 days]
Read and Write
5Ch/092d
Vercycle
Interval between auto verifies [1 hour to 90 days]
Read and Write
5Dh/093d
Alr1_flg
What alarm 3 is associated with
0 - oxygen\moist
1 - in calibration
2 - in verify
Read and Write
5Eh/094d
Alm3_flg
Configuration for oxygen alarms, high or low. If a bit
is 1, that is the condition that the indicated alarm
will trip on.
bit 0 - low Dry oxygen
bit 1 - high Dry oxygen
bit 0 - low Wet oxygen
bit 1 - high Wet oxygen
bit 0 - low Moisture
bit 1 - high Moisture
Read and Write
5Fh/095d
Gas_ctr
Which gas is currently flowing to the sensor, 0 is span
gas flowing, 1 is zero gas flowing
Read only
60h/096d
Calflag
Which type of calibration the unit is in:
0 - In normal calibration
1 - In verify
2 - In primary cal
3 - In none of the above, normal operation
Read only
61h/097d
Reserved
N/A
62h/098d
Dry_Cal_variable
The dry calculated percent value that 0 mv would cor
-
respond to with the cell that is currently being used.
This value can vary between different cells. It is
calculated during calibration and used in the dry oxy
-
gen calculations.
Read only
Содержание CEM/Humox
Страница 20: ...2 4 Thermox CEM Humox Analyzer This page intentionally left blank ...
Страница 38: ...3 18 Thermox CEM Humox Analyzer Figure 3 16 Series 2000 alarm connections example ...
Страница 40: ...3 20 Thermox CEM Humox Analyzer Figure 3 17 Series 2000 2 wire RS 485 communication connection ...
Страница 42: ...3 22 Thermox CEM Humox Analyzer Figure 3 18 Series 2000 4 wire RS 485 communication connections ...
Страница 44: ...3 24 Thermox CEM Humox Analyzer ...
Страница 76: ...4 32 Thermox CEM Humox Analyzer This page intentionally left blank ...
Страница 105: ...Service and Parts 7 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 107: ...Service and Parts 7 5 Figure 7 1 Cell replacement ...
Страница 130: ...B 4 Thermox CEM Humox Analyzer This page intentionally left blank ...
Страница 134: ...C 4 Thermox CEM Humox Analyzer Figure C 1 Modulation of external power supply OPTIONAL ...
Страница 136: ...D 2 Thermox CEM Humox Analyzer This page intentionally left blank ...