Appendix C: Configuration Reference
177
fax_log
Use this option to log data about files (not messages) that are faxed. Amanda creates a
log file in the C:\AMANDA directory and logs:
•
The names of the files that were faxed
•
The telephone numbers to which the files were sent
By default, no filename is used and no log is written. Use a maximum of 20 characters.
We recommend using 'FAX.LOG'.
The default appears in install.cfg as:
set fax_log ''
fax_max_retries
Defines the maximum number of times, after the first, to retry sending a fax file if it is
unsuccessful. This is used only when sending the fax in two-call mode (where the caller
enters a fax telephone number and the fax modem sends the file to that number).
The range is 0 to 9. The default is 1.
The default appears in install.cfg as:
set fax_max_retries 1
fax_receive_reverse
True or False. Depends solely on the fax modem you are using. For most Rockwell-
chipset-based Class 2 modems, this parameter should be True. For most other modems
(including Class 2.0), it should be False.
If set incorrectly, received faxes cannot be retransmitted or viewed at all. Setting it to
True reverses the bits within each received byte, correcting for an oddity in the Rock-
well firmware.
The default appears in install.cfg as:
set fax_receive_reverse true
fax_receive_speed
The maximum speed for receiving faxes.
The value can be '0', '1', '3'. Use '0' for 2400 bps, '1' for 4800 bps, and '3' for 9600 bps.
Normally a value of '3' works for 486 CPUs at 25MHz or higher (and is the default). If
you experience data loss on your faxes, lower this setting.
The default appears in install.cfg as:
set fax_receive_speed '3'
fax_requeue_interval
Defines the number of minutes to wait between retries.
The range is 1 to 99. The default is 5.
See also max_retries.
The default appears in install.cfg as:
set fax_requeue_interval 5
fax_reset
Defines the reset command to send to your fax modem when DTR (Data Terminal
Ready) is dropped. For most Rockwell-based fax modems, it should be '&D3', which is
the default.
Possible values: See your fax modem manual. Use a maximum of 20 characters.
The default appears in install.cfg as:
set fax_reset '&D3'
fax_send_reverse
True or False, depends solely on your Class 2 or Class 2.0 fax modem. For most fax mo-
dems, this option should be False.
The default appears in install.cfg as:
set fax_send_reverse false
Fax Options (Continued)
Configuration Option
Description
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...