20
Installing [email protected]
5.
Select “AUTO RUN” by pressing F6.
To define the Ring No Answer (RNA) tone pattern:
1.
Type a telephone number for an extension in the Phone No. field. This extension
number must not be forwarded, not in a hunt group, not in hands free/speaker phone
mode, and not be answered by anyone.
2.
Type 3 in the Verification Count field. This is the number of times you want to run the
test.
3.
Type 10 in the Minimum Cycles field. This is the number of rings AccuCall Plus will
listen to before completing the test cycle.
4.
Select Full (the default) as the value for the Frequency Range field.
The possible values are:
Full (300 Hz to 1700 Hz)
High (800 Hz to 1700 Hz)
This is the range of frequencies that AccuCall Plus listens to.
5.
The Frequencies Detected Window displays the frequencies detected by AccuCall
Plus to characterize the tone.
6.
The Cadence Detected Window displays the cadence that AccuCall Plus detected to
characterize the tone. (This is displayed as a horizontal bar graph.)
7.
Press F9 to begin the test.