Appendix C: Configuration Reference
181
n_rings
Sets the number of rings that Amanda waits before answering a call on a given port. To
have port 7 answer after the second ring use
n_rings 2 for port 7
. This is useful for
those telephone switching systems that do not allow incoming lines to ring in a station
hunt group or do not provide delayed ringing. Also, it may be used to set up backup an-
swering for a secondary attendant operation.
The rings range from 0 to 9.
N
OTE
:
There is a side-effect. When users want to pickup their messages, they must wait the spec-
ified number of rings before Amanda answers.
The default appears in install.cfg as:
set n_rings 1 n
where 1 is the number or rings and
where n is a port number from 1 to 24.
pbx
Indicates which Amanda telephone ports are connected to which PBXs. You provide the
PBX's number (usually 1 or 2).
The defaults appear in install.cfg as:
set pbx 1 n
where 1 is the PBX number and
where n is a port number from 1 to 24.
Serial Port Options
Configuration Option
Description
baud1
baud2
baud3
baud4
The bps (bits per second) for the logical serial port with the same number. For example,
baud1 gives the bps for serial_port1. (Serial_port1 can be mapped to any COM port.)
Possible values: Any valid bps rate. The default is 19200.
The defaults appear in install.cfg as:
set baudn 19200
where
n
is the logical serial port 1, 2, 3, or 4.
databits1
databits2
databits3
databits4
The number of data bits for the logical serial port with the same number. For example,
databits1 gives the number of data bits for the COM port defined as serial_port1.
(Serial_port1 can be mapped to any COM port.)
Possible values are 7 or 8. The default is 8.
The defaults appear in install.cfg as:
set databitsn 8
where
n
is the logical serial port 1, 2, 3, or 4.
parity1
parity2
parity3
parity4
The parity for the logical serial port with the same number. For example, parity1 gives
the parity for serial_port1. (Serial_port1 can be mapped to any COM port.)
Possible values are none, even, odd, mark, or space. The default is none.
The defaults appear in install.cfg as:
set parityn none
where
n
is the logical serial port 1, 2, 3, or 4.
Per Port Options (Continued)
Configuration Option
Description
For reference purposes, the per port options are listed here in alphabetical order. In the Setup utility, they are listed:
pbx, box_grt, box_idx, box_snd, n_rings, and hangup_supervision.
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...