Chapter 9: Using Serial Integration
67
N
OTE
:
To modify the above for another digit plan, use the appropriate number
of
r
’s,
b
’s,
s
’s,
e
’s, and
x
’s. In the example, 20 is used (causing Amanda
to timeout after 2 seconds if the packet has not been received) because it
works for all serial integration. The number is in tenths of seconds.
To program the message waiting lights for NEC 2000, use the following in the Method
field of the two notification records used for Light ON and Light OFF:
To program the message waiting lights for NEC 2400 IMG, use the following in the
Method field of the two notification records used for Light ON and Light OFF:
N
OTE
:
These examples uses
logical serial port 1
; for other ports, the 1’s would
have to be replaced.
AT&T System 75 or Definity-G3
If you use AT&T System 75 or Definity-G3 (smdi_type s75), call Amanda Company
customer support for more information. Call to be faxed Technical Note 14, “Serial
Integration for System 75 and Definity-G3.”
To set configuration options for use with System 75 and Definity-G3:
1.
Follow steps 1 through 11 in the Bellcore Standard SDMI procedure “To modify
configuration options for use with Bellcore Standard SMDI:” in the “Bellcore
Standard SMDI” section.
2.
Change the smdi_type option to:
smdi_type 's75'
N
OTE
:
Type 's75' with a lower case 's'. This option is case sensitive.
3.
Modify
smdi_base_port 1
if the first port on the telephone switching system is
not 1. For example, some telephone switching systems use the port’s extension or
another logical terminal number to identify the port. The first port may be extension
210, with the second port 211, etc. (These numbers must be consecutive.) For exam-
ple, if the first or base port is 210, you use
smdi_base_port 210
.
4.
You can also set
smdi_delay x
, where
x
is a number of tenths of seconds causes
Amanda to wait that long after the call is answered before looking for integration
information. This allows more than one packet to be sent to a port per telephone call.
Amanda uses the last (most recent) packet. The default is 0.
5.
Press F10 to save your changes.
The Save All Data? dialog box appears.
integration 20
'432xxttttxxxxxxxxxxx'
Light ON:
@S(1,’\002’)S(1,’0!A1’)S(1,’%U’)S(1,’\003’)
Light OFF:
@S(1,’\002’)S(1,’0!A5’)S(1,’%U’)S(1,’\003’)
Light ON:
@S(1,’\002’)S(1,’0!B2’)S(1,’%U’)
S(1,’0000000001’)S(1,’\003’)
Light OFF:
@S(1,’\002’)S(1,’0!B6’)S(1,’%U’)
S(1,’0000000001’)S(1,’\003’)
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...