68
Installing [email protected]
6.
Press Y for Yes.
N
OTE
:
The smdi_max, smdi_pretimeout, smdi_start, smdi_stop, and smdi_term
configuration options do not apply to AT&T System 75 and Definity-G3
telephone switching systems.
You must modify your C:\AMANDA\PDX.DB\1001.PBX file to properly integrate the
7404D set information. Using either the Amanda Setup utility or the JOVE utility, verify
that your integration lines are:
integration 10
'
xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxrrr D
'
integration 10
'
xxxxxxxxxxxxsssxxxxxxxxxxxxxxxxrrr D
'
integration 10
'
xxxxxxxxxxxxxx*xxxxAxxxxxxxxxxxrrr C
'
integration 10
'
xxxxxxxxxxxxeeexxxxAxxxxxxxxxxxxxx C
'
integration 10
'
xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxbbb B
'
integration 10
'
xxxxxxxxxxxxsssxxxxxxxxxxxxxxxxbbb B
'
integration 10
'
xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxrrr S
'
integration 10
'
xxxxxxxxxxxxsssxxxxxxxxxxxxxxxxrrr S
'
integration 10
'
xxxxxxxxxxxxxx*xxxxxxxxxxxxxxxxrrr x
'
integration 10
'
xxxxxxxxxxxxsssxxxxxxxxxxxxxxxxrrr x
'
N
OTE
:
The integration lines above are for a three (3) digit station plan. When
you have a mixed dialing plan, (for example, 3 and 4 digit extensions)
you must have integration strings to handle
ALL
possible combinations.
To modify to another digit plan, use the appropriate number of r’s, b’s,
s’s, e’s, and x’s. The proper integration lines vary depending on your
System 75 software release, digital telephone set model, and the data car-
tridge that you use in the digital set. If you experience problems with the
integration strings defined above, run option 3 in the Setup utility (Inte-
gration Helper) to assist you, or contact Amanda Company customer
support.
Also, you need to defined the telephones system dial code “What to dial when a port goes
off-hook” with the code you defined above in FEATURE ACCESS CODE Call Pickup
Access Code.
Finally, you must create mailboxes for each extension number where Amanda’s ports are
connected. The parameters must be defined as follows:
Extension: @G(990)
Do Not Disturb: OFF LOCK: ON
Store Messages? NO
Chains RNA: 990
Chains Busy: 990
Mailbox 990 is the default Company Greeting mailbox. If you have redefined the
Company Greeting mailbox for any of the ports, use that mailbox instead of 990.
N
OTE
:
The examples use %U (for mailbox), but you may prefer %E (for Exten-
sion field) or %V (for Variable field). You can use %E when the Exten-
sion field contains only the extension number. (For example, if the
Extension field contains an H for a blind transfer or starts with a @, %E
is unusable.) You can use %U only if the mailbox is the same as the ex-
tension number. If you use %V, the Variable field in the notification
record must contain the extension number.
Light ON:
*4%U
Light OFF:
#4%U
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...