Chapter 9: Using Serial Integration
69
The *4 and #4 are the AT&T default values, often left as the standard, but fully
configurable. Watch out for dialplan conflicts if you change them because the conflicts
can slow down system operation if a needed wait for dial timeout (that is, a four-digit
speedial code) has the same first few digits as the message waiting light feature.
Ericsson MD-110
This section covers serial integration for the Ericsson MD-110 system.
To set configuration options for serial integration on Ericsson MD-110:
1.
Follow steps 1 through 11 in the Bellcore Standard SDMI procedure “To modify
configuration options for use with Bellcore Standard SMDI:” in the “Bellcore
Standard SMDI” section.
2.
Change the smdi_type option to:
smdi_type 'md110'
3.
Modify
smdi_base_port 1
if the first port on the telephone switching system is
not identified as the logical port 1. For example, some telephone switching systems
use the port’s extension or another logical terminal number to identify the port. The
first port may be extension 241, with the second port 242, etc.
These numbers must
be consecutive.
For example, if the first or base port is 241, you use
smdi_base_port 241
.
4.
You can also set
smdi_pretimeout x
, where
x
is the maximum number of sec-
onds that a packet can precede the forwarded call. Start with 50, the default, but you
may need to experiment to determine the best setting.
5.
Set the smdi_start option to the number of digits in your extension plan. For example,
the following indicates that you have three-digit extensions.
smdi_start 3
6.
(Optional) Set the smdi_stop option to the number of digits in your port number infor-
mation that the telephone switching system will send. This number will usually be 2.
smdi_stop 2
7.
You can also set
smdi_delay x
, where
x
is a number of tenths of seconds.
Amanda waits that long after the call is answered before looking for integration infor-
mation. This allows more than one packet to be sent to a port per telephone call.
Amanda uses the last (most recent) packet. The default is 0.
N
OTE
:
The smdi_max and smdi_term configuration options do not apply to
Ericsson MD-110 telephone switching systems.
You must also modify your C:\AMANDA\PBX.DB\1001.PBX file to include the SMDI
information. Using the Amanda Setup utility (selection 3) or the JOVE utility, verify that
your integration lines are as follows. When using Setup, type 10 in the Timeout field. (10
equals 10 tenths of seconds or a total of 1 second.) Then enter the integration strings in the
column for the station plan your system uses.
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...