To program the message waiting lights, use the following in the Method field
of the two notification records used for Light ON and Light OFF:
N
OTE
:
The message codes above are for a 4-digit and 3-digit sta-
tion plan. To modify to another digit plan, use the appropri-
ate number of
0
's. These examples use
logical serial port 1
;
for other ports, the 1’s would have to be replaced.
NEC 2000 and NEC 2400
This section covers serial integration for NEC 2000 and NEC 2400 systems.
To set configuration options for serial integration on NEC 2000 or NEC
2400:
1.
Follow steps 1 through 11 in the Bellcore Standard SDMI procedure “To
modify configuration options for use with Bellcore Standard SMDI:” in
the “Bellcore Standard SMDI” section.
2.
Change the smdi_type option to:
smdi_type 'necmci'
3.
Modify
smdi_base_port 1
if the first port on the telephone switch-
ing system is not identified as the logical port 1. For example, some tele-
phone switching systems use the port’s extension or another logical
terminal number to identify the port. The first port may be extension
241, with the second port 242, etc.
These numbers must be consecu-
tive.
For example, if the first or base port is 241, you use
smdi_base_port 241
.
4-digit Station Plan
Light ON:
@S(1,'OP:MWI 000%U!\D')
Light OFF:
@S(1,'RMV:MWI 000%U!\D')
3-digit Station Plan
Light ON:
@S(1,'OP:MWI 0000%U!\D')
Light OFF:
@S(1,'RMV:MWI 0000%U!\D')
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...