146
Installing [email protected]
Problem:
Wrong type of notification record.
Solution:
Be sure you selected the right type for the notification record. For example, the notifi-
cation record that turns the message light off must have the type PICKUP.
Problem:
Max Times is set for 0.
Solution:
Make the value in the Max Times field in the Notify record greater than zero.
Host/Remote Programs Do Not Work
If the Host and Remote programs do not work, one of the following may be causing the
problem. See “Chapter 10: Accessing Amanda Remotely.”
Problem:
Both modems used have a bps higher than 2400.
Solution:
Make sure you use /f on the command line if both modems are faster than 2400 bps
(bits per second).
Problem:
Host is not loaded in the AUTOEXEC.BAT file or has not been loaded manually.
Solution:
Check your AUTOEXEC.BAT to see if “rem” is in front of
LH HOST /4 statement. Or type LH HOST /x with the COM port x at the DOS prompt
(C:\).
Problem:
Host is installed on the wrong COM port.
Solution:
Check what COM port your modem is using and change the LH HOST statement to
use that port number.
Be sure that the host program is not using the same COM port as any other process, such
as SMDI or your fax modem.
Problem:
An internal modem is being used and there is an IRQ or a COM port conflict with
the computer’s controller card.
Solution:
Check your computer’s controller card and verify that your modem’s COM port is dis-
abled on the controller card.
Problem:
Remote is installed on a COM port other than COM 1 or 2.
Solution:
To use the Remote program, the modem must use only COM 1 or COM 2. Verify that
the modem is set for one of these ports. Then run the remote program designating the
correct port.
Problem:
Other communications software is still running.
Solution:
Remove all other remote software from the computer’s AUTOEXEC.BAT file and do
not load any other remote software manually.
Message: RDSP Not Located at Any Interrupt Vector
If you see the RDSP Not Located at any Interrupt Vector message, one of the following
may be causing the problem.
Problem:
The CMOS settings are incompatible.
Solution:
Make sure the CMOS settings disable all adapter ROM shadowing or shadow RAM,
except for the F000 (hexadecimal) segment/system ROM shadow.
Problem:
The Exclusion statement in CONFIG.SYS is incorrect.
Solution:
Back up your existing CONFIG.SYS, AUTOEXEC.BAT, and \PLATFORM\CON-
FIG files
.
Then try to rerun, from the C:\ prompt, 1STTIME.BAT to reconfigure your PC’s memory.
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...