156
Installing [email protected]
busycycles
Minimum number of non-ringback cycles necessary before the Rhetorex driver notifies
Amanda that the extension is busy.
The default is 2 cycles. The range is 0 to 20. 0 means do not change the current Rhetorex
setting (which is also 2 cycles).
The default appears in install.cfg as:
set busycycles 2
ca_file
The file (in the C:\AMANDA directory) which stores call accounting (SMDR) data that
comes from the port in ca_port. The data is collected from the telephone switching sys-
tem, stored while Amanda runs, and then (after a shutdown) read by a call accounting
package that analyzes and manipulates the data.
Use any filename. The default is 'SMDR.DAT'.
See also ca_port.
The default appears in install.cfg as:
set ca_file 'SMDR.DAT'
ca_port
The number for the logical serial port that will read SMDR data from the switch while
Amanda is running. The data is stored in the file specified by ca_file unless the number
is 0, in which case no SMDR data is read.
Use 0, 1, 2, 3, or 4. The default is 0.
See also ca_file.
The default appears in install.cfg as:
set ca_port 0
cancel_busy_hold
Determines whether callers can hold for a busy extension.
True or False. The default is False.
When True, busy becomes equivalent to Ring No Answer (RNA). That means that the
caller cannot hold for a busy extension and can only leave a message once RNA or
BUSY is the state of the called extension (assuming the mailbox accepts messages).
When False, the caller can press * to hold for a busy extension.
The default appears in install.cfg as:
set cancel_busy_hold false
clock_sync
Controls whether Amanda resynchronizes the DOS software clock with the PC hardware
clock.
True or False. The default is True.
When True, Amanda resynchronizes.
When False, Amanda does not resynchronize. Turn this off if you have another utility
that controls the PC clock.
The default appears in install.cfg as:
set clock_sync true
cmt_maxlen
Sets the total number of seconds allowed for recording a List Comment. The user can
record a comment while creating a mailing list or later. It names or describes the con-
tents of the list.
Number of seconds. The range is from 1 to 99. The default is 10.
The default appears in install.cfg as:
set cmt_maxlen 10
General Options (Continued)
Configuration Option
Description
Содержание [email protected] Version 3.xx
Страница 1: ...Installing AmAndA Work Place Version 3 xx Installer s Guide Edition 7 01...
Страница 4: ...iv Installing Amanda Work Place...
Страница 60: ...52 Installing Amanda Work Place...
Страница 68: ...60 Installing Amanda Work Place...
Страница 132: ...124 Installing Amanda Work Place...
Страница 150: ...142 Installing Amanda Work Place...
Страница 156: ...148 Installing Amanda Work Place...
Страница 194: ...186 Installing Amanda Work Place...
Страница 206: ...198Installing Amanda Work Place...