3. Installation
35
6-Route Pin
In this case, use a 2.5 mm² wire. Crimp the specified terminals to the given wire (2.5 mm²) in each
route.
ATTENTION:
Use terminals with length A = 12 mm to ensure effective contact (see Figure 3-18).
10-Route Pin
In this case, use wires from 0.5 mm² to 1.5 mm². Cut each wire with an 8 mm gap, as indicated in
Figure 3-17. Crimp the specified terminals to the given wire (0.5 mm² to1.5 mm²) in each route.
ATTENTION:
Use terminals with length A = 12 mm to ensure effective contact (see Figure 3-18).
Figure 3-17. Wire Cutting
Figure 3-18. Terminal
Wiring Assembly
Place the terminals into the terminal block from pin number 10, to the 10-route terminal. Make sure
that the terminals are fully inserted and properly connected into the terminal.
Wiring Cramping
Rotate the cables so that they are properly fit and settle them with a plastic wrapping (Figure 3-19).