hypercharger - Operation Instructions and Installation Guide
Version 1-1C
9
Technical
specifications
Page 53 of 57
All rights reserved. The reproduction of this document, also partially, is allowed only with authorization by alpitronic s.r.l.
Rated peak withstand current I
pk
10kA (peak)
Rated short-time withstand current I
cw
4kA (rms)
Table 21:
Electrical connection for HYC_150
HYC_225
Parameter
Nominal value
Operating voltage
N +PE (±10%)
Frequency
50Hz (±5%)
Nominal current
max. 375A
Maximum protection (backup)
500A gG
Connection terminals cross section
connecting bolt 2x12mm
Rated peak withstand current I
pk
10kA (peak)
Rated short-time withstand current I
cw
4kA (rms)
Table 22:
Electrical connection for HYC_225
HYC_300
Parameter
Nominal value
Operating voltage
N +PE (±10%)
Frequency
50Hz (±5%)
Nominal current
max. 500A
Maximum protection (backup)
630A gG
Connection terminals cross section
connecting bolt 2x12mm
Rated peak withstand current I
pk
10kA (peak)
Rated short-time withstand current I
cw
4kA (rms)
Table 23:
Electrical connection for HYC_300