hypercharger - Operation Instructions and Installation Guide
Version 1-1C
Page 16 of 57
3
Product
description
All rights reserved. The reproduction of this document, also partially, is allowed only with authorization by alpitronic s.r.l.
The following figure shows the DC-output switchgear of the HYC_075 and the HYC150:
Figure 10:
DC output switchgear of the HYC_075 and the HYC_150
The following table describes the single components highlighted in the table above:
Identifier
Description
-BC1
DC fault current monitoring for AC charging (optional, only when AC-socket is
present)
-BE1
DC-meter for DC-outlet 1
-BE2
DC-meter for DC-outlet 2 (optional)
-BE3
AC meter
-BX1.1, -BX2.1
DC-outlet 1 isolation monitoring device
-BX2.2, -BX1.2
DC-outlet 1 isolation monitoring device (optional, only when DC-outlet 2 is
present)
-FC1.1, FC1.2
DC-outlet 1 fuses
-FC2.1, FC2.2
DC-outlet 2 fuses