hypercharger - Operation Instructions and Installation Guide
Version 1-1C
3
Product
description
Page 21 of 57
All rights reserved. The reproduction of this document, also partially, is allowed only with authorization by alpitronic s.r.l.
The following figure shows the AC input switchgear of the HYC_225 and the HYC_300:
Figure 15:
AC input switchgear of the HYC_225 and the HYC_300
The following table describes the single components highlighted in the figure above:
Identifier
Description
-FA1
Lightning protection and EMI filter device
-FB1
32A circuit breaker with fault current monitoring AC charging / 4P
-FB2
16A circuit breaker with fault current monitoring for auxiliary 230Vac / 4P
-QA1, -QA2,
-QA3, -QA4
125A circuit breaker / 3P / 16kA
-QB1
500A main switch / 4P
-TB1
Auxiliary 24V power supply
-XD1
Mains input busbars
-XF1
Ethernet network dose
Table 9:
AC input switchgear components for hypercharger HYC_225 and HYC_300