Chapter 6: Configuring Switches for Stacking
152
awplus# write
Building configuration ...
[OK]
awplus#
Enter the WRITE command to
save your change.
If this is the initial management
session of the switch, the WRITE
command automatically adds to
flash memory a new configuration
file called DEFAULT.CFG to store
your configuration change. You
can change the name of the file or
designate a different file after you
create the stack.
awplus# reboot
reboot system? (y/n):
awplus#
Restart the switch with the
REBOOT command
Type “Y” for yes.
Wait three minutes for the switch to
initialize its management software.
Check the ID LED and do one of
the following:
- If the ID LED is displaying a
number from 1 to 4, VCStack is
now enabled on the switch. Go to
the next step.
- If the ID LED is still displaying “0,”
repeat this procedure. Be sure to
issue the WRITE command to
save your change.
Go to “Designating Trunk Ports” on
page 153:
Table 13. Commands for Enabling the VCStack Feature (Continued)
Command
Description
Содержание AT-FAN08
Страница 10: ...Figures 10...
Страница 12: ...Tables 12...
Страница 16: ...Preface 16...
Страница 38: ...Chapter 1 Overview 38...
Страница 60: ...Chapter 2 Virtual Chassis Stacking 60...
Страница 80: ...Chapter 4 Installing the Chassis 80 Figure 32 Chassis Orientations in the Equipment Rack Continued...
Страница 82: ...Chapter 4 Installing the Chassis 82 Figure 34 Example of Adjusting the Equipment Rack Brackets...
Страница 104: ...Chapter 4 Installing the Chassis 104...
Страница 140: ...Chapter 5 Powering On the Chassis 140...
Страница 166: ...Chapter 7 Cabling the AT XEM2 Line Card Ports 166...
Страница 214: ...Appendix A Technical Specifications 214...