1
Upper air chamber
2
diaphragm
3
Lower chamber
4
O-ring ø29x3
5
Nut M8
6
M8 screw
7
Paper gasket
8
Air valve
Fig. 16/3 Description of the pump - air reservoir
1
Valve
2
O-ring valve
3
Nut M8
4
Washer M8
5
Pressure and suction lines
Fig. 16/4 Pump description - Rim
1
Circlip
2
Shaft sealing ring 35-62-12
3
bearing AR 63072RS
4
demarcation cushion
5
Connecting rod retaining ring
6
Crankshaft
7
Needle roller bearing NK55/35
8
M8 screw
9
Pump housing cover
10
Paper gasket
Fig. 16/5 Description of the pump - shaft
16.4.2
Check the oil level
-
Use only branded universal oil 20W30 or 15W40.
Attention!
-
Make sure that the oil level is accurate. Both too low and too high values are harmful.
Oil level.
-
Check that the oil level of the floor pump is visible (Fig. 16/7), the sprayer must be horizontal.
-
If the oil level is low, unscrew the cap and top up with oil.