![Agilent Technologies DSO-X 4022A Скачать руководство пользователя страница 440](http://html1.mh-extra.com/html/agilent-technologies/dso-x-4022a/dso-x-4022a_user-manual_2868638440.webp)
440
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
26
I2S Triggering and Serial Decode
If you select an "Armed" value that is equal to or greater than the
"Trigger" value, the "Trigger" value will be increased so that it is
always greater than the "Armed" value.
•
Decreasing value
— similar to the description above except the trigger
occurs on a decreasing data word value, and the "Armed" value is
the value to which the data must rise in order to re- arm the trigger.
6
Press the
Base
softkey and select a number base for entering data
values:
•
Binary (2's complement)
.
When Binary is selected, the
Bits
softkey appears. This softkey opens
the I2S Bits Menu for entering data values.
When the trigger qualifier requires a pair of values (as with In
Range, Out of Range, Increasing value, or Decreasing value), the first
softkey in the I2S Bits Menu lets you select which value of the pair.
In the I2S Bits Menu, press the
Bit
softkey and rotate the Entry knob
to select each bit; then, use the
0 1 X
softkey to set each bit value to
zero, one, or don't care. You can use the
Set all Bits
softkey to set all
bits to the value chosen on the
0 1 X
softkey. Don't care values are
only allowed with Equal or Not Equal trigger qualifiers.
•
Signed decimal
.
When Decimal is selected, the softkey(s) to the right let you enter
decimal values with the Entry knob. These softkeys can be
Data
,
<
,
>
,
or
Threshold
depending on the selected trigger qualifier.
7ULJJHUYDOXH
7ULJJHU
7ULJJHU
1RWULJJHU
$UPHGYDOXH
Содержание DSO-X 4022A
Страница 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 26: ...26 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 62: ...62 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 1 Getting Started...
Страница 78: ...78 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 118: ...118 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 4 Math Waveforms...
Страница 142: ...142 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 148: ...148 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 156: ...156 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 204: ...204 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 10 Triggers...
Страница 240: ...240 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 270: ...270 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 14 Measurements...
Страница 286: ...286 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 322: ...322 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data...
Страница 328: ...328 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 362: ...362 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 366: ...366 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 404: ...404 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 23 CAN LIN Triggering and Serial Decode...
Страница 414: ...414 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 24 FlexRay Triggering and Serial Decode...
Страница 480: ...480 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 29 USB 2 0 Triggering and Serial Decode...