Cursors
13
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
233
•
Track Waveform
— As you move a marker horizontally, the vertical
amplitude of the waveform is tracked and measured. The time and
voltage positions are shown for the markers. The vertical (Y) and
horizontal (X) differences between the markers are shown as
Δ
X and
Δ
Y values.
•
Measure
— When measurements are displayed, this mode shows the
cursor locations used to make the measurement. When you add a
measurement, it becomes the one that cursors are displayed for. You
can use the
Measurement
softkey or touch in the Meas sidebar dialog
to select the measurement whose cursor locations are displayed.
•
Binary
— Logic levels of displayed waveforms at the current X1 and
X2 cursor positions are displayed in the Cursor sidebar dialog in
binary. The display is color coded to match the color of the related
channel's waveform.
•
Hex
— Logic levels of displayed waveforms at the current X1 and X2
cursor positions are displayed in the Cursor sidebar dialog in
hexadecimal.
Manual
and
Track Waveform
modes can be used on waveforms that are
displayed on the analog input channels (including math functions).
Binary
and
Hex
modes apply to digital signals (of MSO oscilloscope
models).
In
Hex
and
Binary
modes, a level can be displayed as 1 (higher than
trigger level), 0 (lower than trigger level), indeterminate state (- ), or X
(don't care).
In
Binary
mode, X is displayed if the channel is turned off.
In
Hex
mode, the channel is interpreted as 0 if turned off.
4
Press
Source
(or
X1 Source
,
X2 Source
in the
Track Waveform
mode); then,
select the input source for cursor values.
Содержание DSO-X 4022A
Страница 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 26: ...26 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 62: ...62 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 1 Getting Started...
Страница 78: ...78 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 118: ...118 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 4 Math Waveforms...
Страница 142: ...142 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 148: ...148 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 156: ...156 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 204: ...204 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 10 Triggers...
Страница 240: ...240 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 270: ...270 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 14 Measurements...
Страница 286: ...286 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 322: ...322 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data...
Страница 328: ...328 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 362: ...362 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 366: ...366 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 404: ...404 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 23 CAN LIN Triggering and Serial Decode...
Страница 414: ...414 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 24 FlexRay Triggering and Serial Decode...
Страница 480: ...480 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 29 USB 2 0 Triggering and Serial Decode...