![Agilent Technologies DSO-X 4022A Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/agilent-technologies/dso-x-4022a/dso-x-4022a_user-manual_2868638153.webp)
Display Settings
8
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
153
To clear the display
1
Press
[Clear Display]
(or press
[Display] > Clear Display
).
You can also configure the
[Quick Action]
key to clear the display. See
"Configuring the [Quick Action] Key"
on page 347.
To select the grid type
When the
Video
trigger type is selected (see
"Video Trigger"
on page 187),
and the vertical scaling of at least one displayed channel is 140 mV/div,
the
Grid
softkey lets you select from these grid types:
•
Full
— the normal oscilloscope grid.
•
mV
— shows vertical grids, labeled on the left, from - 0.3 V to 0.8 V.
•
IRE
— (Institute of Radio Engineers) shows vertical grids in IRE units,
labeled on the left, from - 40 to 100 IRE. The 0.35 V and 0.7 V levels
from the
mV
grid are also shown and labeled at the right. When the
IRE
grid is selected, cursor values are also shown in IRE units. (Cursor
values via the remote interface are not in IRE units.)
The
mV
and
IRE
grid values are accurate (and match Y cursor values)
when the vertical scaling is 140 mV/division and the vertical offset is
245 mV.
To select the grid type:
1
Press
[Display]
(or
[Display] > More
on 1 Ghz and 1.5 GHz bandwidth
models).
2
Press the
Grid
softkey; then, turn the Entry knob
to select the grid
type.
To adjust the grid intensity
To adjust the display grid (graticule) intensity:
1
Press
[Display]
.
Содержание DSO-X 4022A
Страница 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 26: ...26 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 62: ...62 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 1 Getting Started...
Страница 78: ...78 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 118: ...118 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 4 Math Waveforms...
Страница 142: ...142 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 148: ...148 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 156: ...156 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 204: ...204 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 10 Triggers...
Страница 240: ...240 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 270: ...270 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 14 Measurements...
Страница 286: ...286 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 322: ...322 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data...
Страница 328: ...328 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 362: ...362 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 366: ...366 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 404: ...404 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 23 CAN LIN Triggering and Serial Decode...
Страница 414: ...414 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 24 FlexRay Triggering and Serial Decode...
Страница 480: ...480 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 29 USB 2 0 Triggering and Serial Decode...