154
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
8
Display Settings
2
Press the
Intensity
softkey; then, turn the Entry knob
to change the
intensity of the displayed grid.
The intensity level is shown in the
Intensity
softkey and is adjustable from
0 to 100%.
Each major vertical division in the grid corresponds to the vertical
sensitivity shown in the status line at the top of the display.
Each major horizontal division in the grid corresponds to the time/div
shown in the status line at the top of the display.
To display waveforms as vectors or dots
Agilent InfiniiVision 4000 X- Series oscilloscopes are designed to operate
optimally with vectors (connect the dots) on. This mode produces the
most insightful waveforms for most situations.
On the 1 GHz and 1.5 GHz bandwidth models, you can disable vectors to
view just waveform data points.
To disable or re- enable vectors:
1
Press
[Display] > More
.
2
Press
Vectors
.
When enabled,
Vectors
draws a line between consecutive waveform data
points.
•
Vectors give an analog look to a digitized waveform. Complex analog
signals like video and modulated signals show analog- like intensity
information with vectors on.
•
Vectors allow you to see steep edges on waveforms, such as square
waves.
•
Vectors allow subtle detail of complex waveforms to be viewed, much
like an analog oscilloscope trace, even when the detail is just a small
number of pixels in size.
You may want to turn vectors off when highly complex or multivalued
waveforms are displayed. Turning vectors off may aid the display of
multivalued waveforms such as eye diagrams.
Содержание DSO-X 4022A
Страница 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 26: ...26 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Страница 62: ...62 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 1 Getting Started...
Страница 78: ...78 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 118: ...118 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 4 Math Waveforms...
Страница 142: ...142 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 148: ...148 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 156: ...156 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 204: ...204 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 10 Triggers...
Страница 240: ...240 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 270: ...270 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 14 Measurements...
Страница 286: ...286 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 322: ...322 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data...
Страница 328: ...328 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 362: ...362 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 366: ...366 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 404: ...404 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 23 CAN LIN Triggering and Serial Decode...
Страница 414: ...414 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 24 FlexRay Triggering and Serial Decode...
Страница 480: ...480 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 29 USB 2 0 Triggering and Serial Decode...