MMEMory Subsystem
- uploads contents of a file from instrument to host computer
Folder and file formats
Many MMEMory commands refer to folders and files. These have specific structures, described below.
Format for a <
folder
>
l
The format for <
folder
> is "<
drive
>:<
path
>", where <
drive
> can be INTernal or USB, and <
path
> is an absolute
folder path.
l
INTernal specifies the internal flash file system.USB specifies a front panel USB storage device.
l
Absolute paths begin with "\" or "/" and start at the root folder of <
drive
>.
l
The folder name specified in <
path
> cannot exceed 240 characters.
l
The specified folder must exist and cannot be marked hidden or system.
l
If <
drive
>:<
path
> is omitted, the folder specified by
is used.
l
If <
drive
> is omitted:
l
The path is treated as a relative path and appended to the folder specified by
l
Absolute paths are NOT allowed.
Format for a <
file
>
l
The format for <
file1
> and <
file2
> is "[<
drive
>:<
path
>]<
file_name
>", where <
drive
> can be INTernal or USB,
and <
path
> must be an absolute folder path.
l
INTernal specifies the internal flash file system.USB specifies a front panel USB storage device.
l
If <
drive
>:<
path
> is omitted, the folder specified by
is used.
l
Absolute paths begin with "\" or "/" and start at the root folder of <
drive
>.
l
Folder and file names cannot contain the following characters: \ / : * ? " < > |
l
The combination of folder and file name cannot exceed 240 characters.
l
The source file and folder and the destination folder must exist and cannot be marked hidden or system.
l
If the destination file exists, it is overwritten, unless marked as hidden or system.
l
If <
drive
> is omitted:
l
The path is treated as a relative path and appended to the folder specified by
l
Absolute paths are NOT allowed.
Mass Memory (MMEMory) and State Storage
The front panel uses the MMEM subsystem, not the MEM subsystem, to save states. If you save a state with the front
panel, you can still access it with SCPI. However, a state saved into the MEM subsystem via SCPI using *SAV cannot be
retrieved from the front panel.
Agilent 33500 Series Operating and Service Guide
251
Содержание Agilent 33500 Series
Страница 1: ...Agilent Technologies 33500 Series Waveform Generator Operating and Service Guide ...
Страница 68: ...Output Configuration OUTPUT SYNC SOURCE CH1 CH2 Agilent 33500 Series Operating and Service Guide 67 ...
Страница 410: ...Block Diagram Block Diagram Agilent 33500 Series Operating and Service Guide 409 ...
Страница 429: ......