Note
U,
V,
and
W-band
p o
w
er
sensors
are
not
a
v
ailable
from
Agilent
T
ec
hnologies.
F
or
these
frequencies
use
the
Anritsu
ML83A
P
o
w
er
Meter
with
the
MP715-004
(40
to
60
GHz),
the
MP716A
(50
to
75
GHz),
or
the
MP81B
(75
to
110
GHz)
p o
w
er
sensors.
Since
the
Anritsu
mo
del
ML83A
P
o
w
er
Meter
is
not
capable
of
in
ternally
storing
p o
w
er
sensor
cal
factors,
y
ou
m
ust
man
ually
correct
the
data
en
try
.
Refer
to
example
2
for
information
on
man
ual
en
try
of
correction
data.
Setup
Sw
ept
Signal
Generator
P
arameters
5.
T
urn
on
the
sw
ept
signal
generator
and
press
4
PRESET
5.
The
following
o ccurs:
The
source
mo
dule's
frequency
span
is
display
ed
on
the
sw
ept
signal
generator.
The
sw
ept
signal
generator's
lev
eling
mo
de
is
automatically
c
hanged
from
in
ternal
to
\mo
dule
lev
eling".
The
source
mo
dule's
maximum
sp ecied
p o
w
er
is
set
and
display
ed.
6.
Press
FREQUENCY
4
ST
ART
5
4
2
5
4
6
5
4
.
5
4
5
5
4
GHz
5,
4
STOP
5
4
4
5
4
0
5
4
GHz
5.
The
frequency
sw
eep
is
set
from
26.5
to
40
GHz.
7.
Press
4
POWER
LEVEL
5
4
7
5
4
dBm
5.
The
source
mo
dule
p o
w
er
is
set
to
+7
dBm
for
maxim
um
p o
w
er
to
the
device
under
test.
Access
User
Flatness
Correction
Men
u
8.
Press
PO
WER
4
MENU
5.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Fltness
Menu
.
9.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Delete
Menu
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Delete
All
.
This
step
insures
that
the
atness
array
is
empt
y
.
10.
Press
4
PRIOR
5.
Lea
v
e
the
delete
men
u
and
return
to
the
previous
softkey
men
u.
11.
Select
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Enter
Freq
4
2
5
4
6
5
4
.
5
4
5
5
4
GHz
5,
to
en
ter
26.5
GHz
as
the
rst
correction
frequency
.
En
ter
31,
32.5,
and
40
GHz
to
complete
the
list.
Notice
that
the
frequencies
are
arbitrarily
spaced.
Getting
Started
Adv
anced
1-41
Содержание 8360B
Страница 10: ...Declaration of Conformity x ...
Страница 53: ...Figure 1 12 Typical Diode Detector Response at 25 C Getting Started Advanced 1 25 ...
Страница 136: ...Figure 1 34 Typical Status Register Bit Changes 1 108 Getting Started Programming ...
Страница 141: ...Figure 1 38 Inside an Event Detection State Getting Started Programming 1 113 ...
Страница 154: ...4ALC5 Figure A 1 ALC System Simplified Block Diagram Operating and Programming Reference A 5 ...
Страница 363: ...SCPI STATUS REGISTER STRUCTURE S 56 Operating and Programming Reference ...
Страница 364: ...SCPI STATUS REGISTER STRUCTURE Operating and Programming Reference S 57 ...
Страница 406: ...2b Menu Maps Menu Maps 2b 1 ...
Страница 407: ......
Страница 408: ......
Страница 409: ......
Страница 410: ......
Страница 411: ......
Страница 412: ......
Страница 413: ......
Страница 414: ......
Страница 415: ......
Страница 438: ...Figure 3 1 AC Power Cables Available Installation 3 5 ...
Страница 469: ...5 Instrument History This chapter is left blank until this manual requires changes Instrument History 5 1 ...