Section 5 – Data Field Descriptions
5-13
FIELD
TITLE and DATA ENTRIES
EXPLANATION
2*00
Number of Partitions
Enter 1-8.
Enter the number of partitions used in the system.
2*01
Daylight Saving Time Start/End
Month
0 = disable
1 = enable
Enter the months (00-12) in which daylight saving time starts and
ends.
Enter 00, 00 if daylight saving time does not apply to the user’s
region. Standard setting for U.S. is 04,10.
2*02
Daylight Saving Time Start/End
Weekend
0 = disable
1 = enable
Enter the start and end weekends for daylight saving time as follows:
1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third
from last. Standard setting for U.S. is 1,5.
UL
Fields 2*05 – 2*08 must be set to 0 for UL installations.
2*05
Auto-Arm Delay (partition-
specific)
00 = no delay.
01-14 times 4 minutes (04-56) delay.
15 = no auto arming.
This is the time between the end of the arming window and the start
of auto-arm warning time (field 2*06).
2*06
Auto-Arm Warning Period
(partition-specific)
01-15 times 1-minute warning.
00 = no warning period.
This is the time that the user is warned by a keypad sounding and
display to exit the premises prior to auto arming of the system.
2*07
Auto-Disarm Delay (partition-
specific)
00 = no delay.
01-14 times 4 minutes (04-56) delay.
15 = no auto disarming.
This is the time between the end of the disarming window and the
start of auto disarming of the system.
2*08
Force Arm Enable for Auto-Arm
(partition-specific)
0 = disable
1 = enable
If enabled, the system automatically bypasses any faulted zones
when it attempts to auto-arm.
If disabled, the system will not auto-arm.
2*09
Open/Close Reports by
Exception (partition-specific)
0 = disable
1 = enable
If enabled, Open/Close reports are sent only if the openings/closings
occur outside the arm and disarm windows.
NOTES:
Open reports are also suppressed during the closing window in order
to prevent false alarms if the user arms the system, then re-enters
the premises, for example to retrieve a forgotten item.
Openings and closings are still recorded in the event log.
This field must be set to 1 if No Opening and No Closing reports are
to be sent.
2*10
Allow Disarming Only During
Arm/Disarm Windows (partition-
specific)
0 = disable
1 = enable
If enabled, disarming of the system is allowed only during the
arming/disarming windows, or if the system is in alarm (if 2*11 is set
to 1).
NOTE: This applies only to Operator-level users. Installer, Master,
and Manager-level users can disarm the system at any time.
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...