VISTA-128B PLUS Installation and Setup Guide
5-14
FIELD
TITLE and DATA ENTRIES
EXPLANATION
2*11
Allow Disarm Outside Window if
Alarm Occurs
0 = disable
1 = enable
If enabled, allows the system to be disarmed outside the programmed
disarm (opening) window if an alarm has occurred. Otherwise
disarming is allowed only during the disarm window.
NOTE: Used only if field 2*10 is enabled.
2*18
Enable GOTO for this Partition
(partition-specific)
0 = disable
1 = enable
If enabled, this partition can be accessed from another partition’s
keypad using the GOTO command.
2*19
Use Partition Descriptor
0 = disable
1 = enable
If enabled, the normal keypad display will include a partition
number and four-digit descriptor.
2*20
Enable J7 Triggers for Partition
(partition-specific)
0 = disable
1 = enable
If enabled, the J7 triggers function for this partition.
2*21
Supervision Pulses for LRR
0 = disable
1 = enable
There are three entries in this field as follows: Fire,
Burglary/Audible Panic, Silent Panic/Duress.
If enabled, causes the control to send periodic short pulses on the J7
radio triggers to the LRR. The LRR uses these pulses to determine
that its connection to the control is still intact.
Must be 1 for UL installations.
2*22
Display Fire Alarms of Other
Partitions (partition-specific)
0 = disable
1 = enable
If enabled, allows fire alarms that occur on other partitions to be
displayed at this partition’s keypad(s).
2*23
Display Burglary & Panic Alarms
for Other Partitions (partition-
specific)
0 = disable
1 = enable
If enabled, allows burglary and panic alarms that occur on other
partitions to be displayed at this partition’s keypad(s).
2*24
Display Troubles of Other
Partitions (partition-specific)
0 = disable
1 = enable
If enabled, allows troubles that occur on other partitions to be
displayed at this partition’s keypad(s).
2*30
Pager Installed
0 = disable
1 = enable
Enable if the alphanumeric pager interface is installed.
2*31
Send Message to Pager After
Dialer
0 = disable
1 = enable
If enabled, sends reports to the pager after the dialer sends the
message to the central station.
2*32
Time to Delay Pager After Dialer
000-024 times 10 seconds (010-240).
This delay should be set to allow the system enough time for the
dialer to send the message(s) to the central station before sending
the message(s) to the pager.
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...