VISTA-128B PLUS Installation and Setup Guide
4-8
Type 07 DIP Switch Loop (DP)
Select for polling loop devices that use DIP switches for
programming the zone number of the device.
Type 08 Serial Number Polling Loop (DS)
Select for the second loop of two-zone polling loop
devices (e.g., 4190WH; 4278).
Type 09 Console Input (CS)
Select when this zone is to be controlled by a keypad
input (user code + [#] + [7] + [3]) for access control.
Type 10 PassPoint Access Control (ACS)
Select when this zone is mapped to a zone on the
PassPoint Access Control System.
Type11 VistaKey Door Status Monitor (DSM)
This input type is used to define the zone that will
monitor when the door (access point) is open. It is used
by the system to be able to determine if the door is
opened after a card swipe or if the door is being held in
an open position. The device is normally a magnetic
switch mounted on the door. The status of the switch is
different when the door (access point) is in an open
condition.
Type 12 VistaKey Request to Exit (RTE)
Use this input type to map an uncommitted RTE zone
to an alarm panel zone. This input type is not normally
used if the zone is used for a request-to-exit function.
Type 13 VistaKey General Purpose (GP)
This input type operates in the same manner as other
VISTA-128B PLUS alarm panel zones and is provided
so that a zone in the proximity of the VistaKey can be
wired without having to run additional wiring from the
VISTA-128B PLUS control panel.
Programming for Panel Linking
Step Action
1
Program the Panel Link Module (PLM) into
the system in Device Programming in the #93
Menu Mode with Device Type 10.
2
If you want to supervise the PLM,
program zone 8xx with response type 05,
where “xx” = the module’s address. If you want
the zone to report to the central station, make
sure the report code for the zone is set with a
non-zero value.
Step Action
3
If you want to supervise the PLMs
connected to other controls, program those
modules in Zone Programming with response
type 14. Also, program the panel ID number.
The ID number must match the ID number
programmed in Device Programming of the
control panel the PLM is connected. If you
want the zone to report to the central station,
make sure the report code for the zone is set
with a non-zero value.
See Device Programming and Zone Programming in #93
Menu Mode Programming in the Programming Guide
for a detailed explanation of the programming
procedures
Programming for the Alpha Pager Module
Programming for TeleSmart
•
In field 2*30, enter 1 to enable the Alpha Pager
Module.
•
Program fields 2*31 – 2*88 for the paging service
parameters (see the Programming Guide).
•
If you have a printer connected to the module,
program field 1*69 with a 0 for a parallel printer or
a 1 for a serial printer.
Fields for programming the delay times (e.g.
2*36 and 2*37 for pager 1) are relevant only
when using numeric format for the pager.
The TeleSmart module has a fixed address of 08 (it
cannot be changed). Set Device Address 08 in the
VISTA-128B PLUS Device Programming mode for
Device Type 11, TeleSmart. Also, Device Address 07
must be set for Device Type 01, Alpha Console, but do
not actually connect a device to the VISTA-128B
PLUS set to that address. This must be done so that
TeleSmart can be accessed remotely (off premises).
Refer to Device Programming in the #93 Menu Mode in
the VISTA-128B PLUS Programming Guide for specific
instructions.
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...