Up & About Programming
Up & About programming provides the ability to insure there is activity from a person within a premises. This is
particularly useful to verify that an elderly person is okay. As long as the person violates (faults) any burglary zone(s),
arms the system, or presses a key on the keypad within a pre-defined time period, the system will not transmit a signal
to the central station.
UL
Up & About Scheduling is not permitted in UL installations.
To enter Up & About programming, do the following:
Enter Scheduling Menu Mode Installer Code + # 80. After entering Scheduling Menu Mode, press [0] until the "UP &
ABOUT PROG?" prompt appears.
PROMPT
EXPLANATION
UP & ABOUT PROG?
1=YES 0=NO
0
Enter [1] at this prompt.
PARTITION # ?
01-08, 00 = Quit
01
Enter the partition (01-08).
Press [
✳
] to accept entry.
Enter 00 to quit Up & About programming and display the “Quit ?” prompt.
01 Time Window
(0-4) hrs
0
Enter the number of hours (1-4) the Up & About feature is to be active.
Enter 0 to disable Up & About for this partition.
Press [
✳
] to accept entry.
01 Start Time
12:00AM
Enter the start time for the Up & About time period.
Enter the hour of the day (01-12). Press [
✳
] to accept entry. The cursor moves to the minutes position.
(Press the [#] to move the cursor backwards.)
Enter the minutes of the hour (00-59). Press [
✳
] to accept entry.
The cursor moves to the AM/PM position. Press [
✳
] to accept the current selection; or press any key (1-9)
except the [
✳
] or [#] to toggle the AM/PM selection.
Press [
✳
] to accept entry.
01 Stop Time
12:00AM
Enter the stop time for the Up & About time period.
Enter the hour of the day (01-12). Press [
✳
] to accept entry. The cursor moves to the minutes position.
(Press the [#] to move the cursor backwards.)
Enter the minutes of the hour (00-59). Press [
✳
] to accept entry.
The cursor moves to the AM/PM position. Press [
✳
] to accept the current selection; or press any key (1-9)
except the [
✳
] or [#] to toggle the AM/PM selection.
NOTE: The time from the Start time to the Stop time must be equal to or greater than the Time Window.
Press [
✳
] to accept entry.
01 Violations
(001-254) 001
Enter the number of violations of a zone required to satisfy the Up & About condition (001-254). If the
number of violations does not occur, an Up & About alarm is generated.
NOTES: The violation count can be completely satisfied by entering User Code + [#] + [76]. In this case,
the Up & About will begin when the next programmed start time is reached. Also, the user can add one
violation to the count by pressing any key on the keypad. There is a 1-minute timeout period before the
user can press another key to add another violation.
Press [
✳
] to accept entry.
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...