Section 3 - Installing the Control
3-31
For Household Fire or Combination Household
Fire/Burglary Installation: The total current drawn
from the auxiliary power, the polling loop, and the
alarm output combined must not exceed 750mA to
comply with the battery independence requirements in
UL985.
For Household Burglary-Only Installations: The
total current drawn from the alarm output may be up
to 1.7A. A battery must be installed to supply the
current of the combined auxiliary power, polling loop,
and alarm output in excess of 750mA.
Failure to observe the polling loop current
rating will cause polling loop malfunction.
Failure to observe the auxiliary power current
rating will result in a battery that does not
charge properly or possibly a tripped circuit
breaker.
To connect the transformer to the control, perform the
following steps:
Step Action
1
Connect all installed devices to the control.
2
Wire the 1361 Transformer (1361CN in
Canada) to the panel (before connecting the
battery) as shown in Figure 3-43, or wire the
4300 Transformer as shown in Figure 3-44
(if using Powerline Carrier devices).
3
Plug the transformer into a 24-hour,
uninterrupted, 120VAC, 60Hz outlet. After
a few seconds, the keypad display appears.
NO CONNECTION
TRANSFORMER
16.5VAC, 40VA
ADEMCO No.1361
or 4300, XM10E, or
XF10 if X-10 DEVICES
WILL BE USED.
Connect to
24hr. source
of AC mains
1
2
3
RED (+)
BLK (-)
Connect to
12VDC, 4AH
or 12VDC, 7AH
GEL CELL
BATTERY
CHARGING
VOLTAGE
13.7 VDC
NOTE:
WHEN POWERING UP
THE PANEL, PLUG THE
TRANSFORMER IN BEFORE
CONNECTING THE BATTERY.
BATTERY
TABS
PRIMARY
POWER
Supplied by a
transformer which
is rated at
16.5VAC, 40VA.
Caution must be
taken when wiring
this transformer to
the panel to guard
against blowing the
fuse inside the
transformer (non-
replaceable).
Figure 3-43: 1321 Transformer and Battery
Connections
1 2
3 4 5 6
7 8
9
GROUND
GROUND
OUT 6
IN 2
GROUND
IN 3
GROUND
OUT 5
J8 CONNECTOR
BLACK
BLUE
BROWN
GREEN
RED
WHITE
YELLOW
GRAY
VIOLET
4142TR CABLE
1
2
3
4
5
6
TB1
-1
TB1
-30
TB1
-2
AC
Earth
Ground AC
Sync Data Com
4300 TRANSFORMER/INTERFACE
Figure 3-44: 4300 Transformer Connections
Panel Earth Ground Connections
In order for the lightning transient protective devices in
this product to be effective, the designated earth ground
terminal (terminal 30) must be terminated in a good
earth ground. Recommended wire gauge for the ground
connection is #16 AWG, run no farther than 30 feet.
The following are examples of good earth grounds
available at most installations:
•
Metal Cold Water Pipe: Use a noncorrosive
metal strap (copper is recommended) firmly
secured to the pipe to which the ground lead is
electrically connected and secured.
•
AC Power Outlet Ground: Available from 3-
prong, 120VAC, power outlets only. To test the
integrity of the ground terminal, use a three-wire
circuit tester with neon lamp indicators, such as
the UL-Listed Ideal Model 61-035, or equivalent,
available at most electrical supply stores.
The panel requires the earth ground
connection for its lightning transient protection
devices.
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...