VISTA-128B PLUS Installation and Setup Guide
1-2
UL
Wireless devices may not be used in UL installations.
•
Can program burglary zones as silent in the alarm condition (alarm output is silent and
the keypad does not display or sound the alarm).
•
Provides three keypad panic keys: 1 +
✴
(A),
✴
+ # (B), and 3 + # (C).
Peripherals Devices
•
Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.).
•
Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up
to 32), as well as system zones (RF receivers and keypad panics).
•
Provides 96 outputs using 4204 and 4204CF Relay Modules, Fire System Annunciators
(FSA-8, FSA-24), V-Plex Relay Modules and Powerline Carrier Devices (X-10) can
activate outputs in response to system events (alarm condition), at a specific time of day,
at random times, and manually using the #70 Relay Command Mode.
•
Supports the ADEMCO 4285/4286 VIP Module, which allows access to the system from
either a remote location or on the premises
UL
The 4285/4286 VIP Module is not Listed for use with the VISTA-128B PLUS Control Panel in a
UL installation
.
•
Supports the ADEMCO 4146 Keyswitch on any one of the system's 8 partitions.
Arming/Disarming and Bypassing
•
Can arm the system with zones faulted (Vent Zone). These zones are automatically
bypassed and can be programmed to automatically unbypass when the zone restores.
•
Can arm with entry/exit and interior type zones faulted (Arm w/Fault). These zones must
be restored before the exit delay expires, otherwise an alarm is generated.
•
Provides global arming capability (ability to arm all partitions the user code has access to
in one command).
•
Can Quick Exit an armed premises without having to disarm and then rearm the system.
•
Can be armed in one of three STAY modes or Instant modes, automatically bypassing
specific burglary zones regardless of the zone response type.
•
Can automatically bypass specific zones if no one exits the premises after arming (Auto-
STAY). Auto-STAY will not occur if the system is armed via an RF transmitter, VIP
module, scheduling, access control, keyswitch, RS232 automation or downloading.
•
Can bypass a group of zones with one set of keystrokes.
•
Supports Exit Error Logic, whereby the system can tell the difference between a regular
alarm and an alarm caused by leaving an entry/exit door open. If the system is not
subsequently disarmed, faulted E/E zone(s) and/or interior zones are bypassed and the
system arms.
•
Supports Recent Close report, which is designed to notify the central station that an
alarm has occurred within 2 minutes after the exit delay has expired.
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...