VISTA-128B PLUS Installation and Setup Guide
3-10
Model Number
Type
4939SN-BR
4939SN-GY
Serial Number Surface-Mount Reed
Contacts
4191SN-WH
Serial Number Recessed Reed Contact
4959SN
Aluminum Overhead Door Contact
7500
Single Technology Glassbreak Detector
9500
Dual Technology Glassbreak Detector
4209U
Universal Group Zoning Module
4193SN Serialized
2-Zone
Expander
4293SN
Serialized 1-Zone Expander
UL
•
The 4208 must be mounted either inside
the VISTA-128B PLUS cabinet or in a
separate enclosure that has a tamper-
supervised cover.
•
The 4190WH right loop must not be used,
and the left loop must be EOLR-
supervised.
•
The 4278 Auxiliary Sensor Loop cannot be
used.
•
The 4194 is not UL Listed.
•
The 4297 must be powered from the
VISTA-128B PLUS Auxiliary Power Output
or from a UL Listed supplementary power
supply.
•
Models 7500 and 9500 glassbreak
detectors are not UL Listed.
To install devices to the polling loop, perform the
following steps:
Step Action
1
Select devices from the list of compatible
devices shown previously.
2
Set the DIP switches in the device (if
required). Refer to the device’s instructions
for the DIP Switch Tables.
3
Mount each device in the desired location.
Refer to the device’s instructions.
Run wires from the control panel to each
device on the polling loop (see Figure 3-16).
No individual wire run may exceed the
lengths shown in the following table.
Maximum Polling Loop Wire Runs
Wire Gauge
Max. Length
#22 gauge
650 feet
#20 gauge
950 feet
#18 gauge
1500 feet
#16 gauge
2400 feet
4
Step Action
5
Wire each device to the polling loop, making
sure to use correct polarity when making
connections (refer to the device’s
instructions).
NOTE: If you are using serial number
devices, and intend to have the control
enroll each serial number automatically,
wire no more than 25 of these devices
to the control at a time. Then power up
and program them before connecting the
next 25. Leave previously enrolled devices
connected.
If you intend to manually enter the serial
numbers through the keypad or through
Compass downloading software, all the
devices may be connected before powering
up to program.
4190
RPM
4278
PIR
Polling loop rating:
128mA maximum.
POLLING LOOP
21
22
23
24
25
+
-
4192SD
SMOKE
TO RIGHT LOOP
Figure 3-16: Polling Loop Connections to the
VISTA-128B PLUS
Using the 4297 Polling Loop Extender
The 4297 Polling Loop Extender may be used to provide
additional polling loop current, to extend the polling
loop wire run length, and/or to provide individual
electrically isolated polling loops. Refer to Figures 3-17
and 3-18, to follow.
DO NOT use the 4197 Polling Loop Extender
module with the VISTA-128B PLUS
.
Be sure to include the total current drawn on
the polling loop when figuring the total auxiliary
load on the panel’s power supply.
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...