VISTA-128B PLUS Installation and Setup Guide
3-14
The wireless system can identify a true low battery
situation, thus allowing the dealer or user of the system
time to arrange a change of battery and maintain
protection for that point within the system.
Some transmitters (e.g., 5802, 5802CP, and 5803)
contain long-life but nonreplaceable batteries. At the
end of their life, the complete unit must be replaced
(and a new serial number enrolled at the control).
Button-type transmitters (e.g., 5801, 5802, 5802CP and
5803) should be periodically tested, as these
transmitters do not send supervisory check-in signals.
To test the transmitters using the Transmitter
ID Sniffer mode and the Go/NoGo Test Mode,
see the
Testing the System section for the
procedures.
Compatible 5800 Series Transmitters
Model Product
Input
Type
5801
Panic Transmitter
UR or RF
5802
5802CP
Pendant (Personal Emergency
Transmitter)
Belt Clip (Personal Emergency
Transmitter)
BR Only
5802MN
Miniature (Personal Emergency
Transmitter)
UR or RF
5804
Wireless Key Transmitter
BR Only
5804BD
Wireless Key Bi-directional
Transmitter
BR Only
5806/5807
/5808
Wireless Photoelectric Smoke
Detectors
RF
5816 Door/Window
Transmitter RF
5817 Multi-Point
Universal
Transmitter
RF
5818 Recessed
Transmitter
RF
5827
Wireless Keypad
House ID
5827BD
Wireless Bi-directional Keypad
House ID
5849 Glassbreak
Detector
RF
5890 PIR
Detector
RF
Installing Output Devices
The VISTA-128B PLUS supports up to 96 outputs to
activate and de-activate as desired. Each device must
be programmed as to how to act (ACTION), when to
activate (START), and when to deactivate (STOP).
The 4204, 4204CF, FSA-8, FSA-24, 4140SN and/or
Powerline Carrier devices may be used as output
devices.
Installing the 4204 and 4204CF Relay Modules
Each 4204 module provides 4 relays with Form C
(normally open and normally closed) contacts. Each
4204CF module adds two style Y supervised bell
outputs to the system. For 4204CF modules, only
relays 1 and 3 on each module can be programmed.
The relay module will not operate until the
device address you have set the DIP switches
for is enabled in the control’s
Device
Programming in the #93 Menu Mode.
To install the relay modules, See Figures 3-20 and 3-21
and perform the following steps:
Step Action
1
Set the 4204 or 4204CF’s DIP switches for a
device address 01-15.
Do not use an address being used by another
device (keypads, RF receivers, etc.).
2
Mount the 4204 and 4204CF Modules per the
instructions provided with them.
Connect the module’s wire harness to the
keypad terminals (6, 7, 8, and 9). Plug the
connector at the other end of the harness into
the module.
If you are mounting remotely, homerun each
module to the control. The table below shows
the maximum wire run lengths from the
control to each 4204. Refer to the instructions
provided with the 4204CF for its maximum
permissible wire lengths.
Wire Gauge
Maximum Length
#22 125
feet
#20 200
feet
#18 300
feet
#16 500
feet
3
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...