VISTA-128B PLUS Installation and Setup Guide
5-2
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*11
Entry Delay #2 (partition-specific)
Enter 02-15 multiplied by 15 seconds.
00 = no delay.
Entry Delay #2 is used for a secondary door requiring a longer delay
than those assigned to Entry Delay #1.
This delay may not exceed 45 seconds for UL installations.
*12
Exit Delay #2 (partition-specific)
Enter 03-15 multiplied by 15 seconds.
00 = no delay.
Exit Delay #2 is used for a secondary door requiring a longer delay
than those assigned to Exit Delay #1.
This delay may not exceed 60 seconds for UL installations.
*13
Bell Timeout (partition-specific)
Enter 01-15 multiplied by 2 minutes.
00 = no timeout.
Defines the length of time the Bell Output and the keypad’s sounder
will sound for all audible alarms.
Must be a minimum of 16 minutes for UL installations.
Burglary or RS232 Input
0 = burglary
1 = RS232 input
If enabled, sets terminal 23 (high side (+) of zone 9) as an RS232
input. This enables the system to receive serial data (75 baud) via
terminal 23.
UL
Using the RS232 input for automation is not permitted in UL installations.
*14
*15
Keyswitch Assignment
Enter 1-8 partition keyswitch is being used.
Enter 0 if the keyswitch is not used.
The keyswitch requires the use of zone 7 wired loop (zone 7 is no
longer available as protection zone). The fire and panic alarm
voltage triggers (J7) automatically become ARMING and READY
status outputs for the Keyswitch LEDs.
Openings/closing report as user “0” if enabled in field *40.
*16
Confirmation of Arming Ding
(partition-specific)
0 = disable
1 = enable
If enabled, produces ½-second external alarm sounding (“ding”) at
the end of exit delay (or after kissoff from the central station, if
sending closing reports).
Must be 1 for UL installations.
*17
AC Loss Keypad Sounding
0 = disable
1 = enable
If enabled, sounding at the keypad (rapid beeping) occurs when AC
power is lost (sounding occurs about 2 minutes after actual AC loss).
*19
Randomize AC Loss Report
0 = disable
1 = enable
If enabled, randomizes AC loss reporting between 10 and 40 min.
after an actual AC loss.
If disabled, AC loss reporting about 2 minutes after actual AC loss.
Selecting this option helps prevent an overload of AC loss messages
at the central station during a community blackout.
*20
VIP Module Phone Code
1-9 = first digit of access code
∗
or # = second digit of access code (enter #
+11 for “
∗
”, or # +12 for “#”)
To disable enter 00 for the 1
st
digit
If a 4285/4286 Voice Module is being used, enter the 2-digit phone
code used to access the system.
Must be disabled for UL installations.
*21
Prevent Fire Timeout
0 = disable (timeout)
1 = enable (no timeout)
If enabled, there is no timeout of the alarm sounder duration for all
fire zones, regardless of partition, so that fire sounding continues
until the system is reset.
If disabled, (timeout) the normal burglary sounder duration (field
✳
13) applies to fire alarms.
*22
Keypad Panic Enables (partition-
specific)
0 = disable
1 = enable
If enabled, the keypad panics (zones 995, 996, and 999) may be used
in this partition. There are 3 entries in this field, one for each panic.
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...