VISTA-128B PLUS Installation and Setup Guide
2-8
Multi-Panel View Mode
To perform a function in the Multi-Panel View mode, follow the steps below:
Step Action
1
Enter User Code (for users 001-050) + [#] + [87].
The keypad displays the following typical display:
ALLPANEL 1 2 3 4 5 6 7 8
STATUS
x x x x x x x x
where “12345678” are the panel ID numbers and “xxxxxxxx” is the overall status
of each panel. Status indications include:
A = Armed Away
S = Armed Stay
M = Armed Maximum
I = Armed Instant
R = Ready
N = Not Ready
B = Bypassed/Ready
✴
= Alarm
T = Trouble
F = Fire Alarm
P = AC Power Failure
L = Low System Battery
C = Comm Fail
NOTE: See table later in this section for priority of displays.
2
The following functions can be performed::
Press [1] to attempt to disarm all partitions on all panels.
Press [2] to attempt to arm AWAY all partitions on all panels.
Press [3] to attempt to arm STAY all partitions on all panels.
Press [4] to attempt to arm MAXIMUM all partitions.
Press [7] to attempt to arm INSTANT all partitions.
Press [0] to exit mode. After a few seconds, the keypad displays the status of the
original partition of the original panel for the keypad. Also, this mode will end in
approximately 120 seconds if no keys are pressed.
NOTES:
When performing any of the arming commands, if there are faults in any of the
partitions of a panel, the system will not arm that panel, but will arm all the other
partitions of the other panels.
When performing either a STAY or INSTANT arm command the system always
arm in mode 1.
The user cannot execute another panel linking mode. In order to perform another
panel linking mode or to access a different remote panel, the user must first exit
this mode (return to the original control panel).
Priority of Displays for Multi-Partition and Multi-Panel Modes
This table shows the priority of displays if more than one of these conditions exists at the
same time.
Priority Description Display
Priority Description Display
1 Fire
Alarm
F
8 Not
Ready
N
2
All Other Alarms
✴
9 Ready
R
3 AC
Loss
P
10 Armed
STAY
S
4 Comm
Fail
C
11 Armed
AWAY
A
5
System Low Battery
L
12 Armed
INSTANT
I
6 Trouble
T
13 Armed
MAXIMUM M
7 Bypass
B
Содержание Vista-128B PLUS
Страница 2: ......
Страница 8: ...viii...
Страница 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...
Страница 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...
Страница 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...
Страница 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...
Страница 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...
Страница 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...