5. SEQUENTIAL DIAGNOSTICS (Optional)
In case the client has ordered the option:
One Sequential Diagnostics kit must be installed for each dimmer cabinet in the installation.
The sequential diagnostics function is similar in function to the diagnostics already used in
the EURODIM 3. The dimmer channels are examined one after the other (sequential) and
the value is reported either to the local Human Interface or a remote program running the
TTD Management Software.
The communication to a single remote reporting pc is done via the proprietary ADB ADN
protocol based on an Ethernet Network to a Personal Computer with the Windows Operating
System running the TTD Management Software. The Ethernet information is generated by
each EURODIM Twin Tech controller and physically available for each individual controller
on dedicated RJ45 connectors (Two possible per cabinet if double controller options are
used).
The TTD Management Software and the necessary hardware are available as option for the
EURODIM Twin Tech cabinet, which shall be ordered separately installation.
Standard functions include
Presence of Mains and DMX signal
Processor (active) check
Over Temperature
Fan Failure (Information per FAN!)
DMX Control Levels
Local test of a dimmer (steady, flash or chaser)
Automatic self-test of control electronics.
Error messages and all events/parameters are available for display locally on the EURODIM
Twin Tech Human Interface Controller and/or remotely on the TT Dimmer Manager PC
connected via an Ethernet Network. (use of ADN protocol)
Scan Load and the related functions are pre-show
1
test routines providing additional
information on the status of each dimmer, i.e.
Value of the dimmer load (kW)
Deviation from reference load
No load, overload warnings
Short-Circuit
The necessary hardware to perform Sequential Diagnostic measurements is an option and
which shall be installed at the client’s site.
1
Sequential Diagnostics cannot be used during a show, since control is disabled and the dimmers
system runs through a test routine.
Содержание EURODIM TWIN TECH
Страница 1: ...Installation Manual V 1 2 EURODIM Twin Tech M 3213 1106 03 213 Lighting Technologies ...
Страница 2: ......
Страница 6: ...EURODIM TWIN TECH www adblighting com Installation manual Page 4 Version 1 2 2 DESCRIPTION ...
Страница 48: ...EURODIM TWIN TECH www adblighting com Installation manual Page 46 Version 1 2 11 6 10 kW Module Connection ...
Страница 61: ...EURODIM TWIN TECH www adblighting com Installation manual Page 59 Version 1 2 Notes ...
Страница 62: ...EURODIM TWIN TECH www adblighting com Installation manual Page 60 Version 1 2 Notes ...
Страница 63: ......
Страница 65: ...EURODIM Twin Tech SF 3213 1106 03 213 Lighting Technologies Quick Start Guide Issue 1 0 ...
Страница 66: ......
Страница 83: ...www adblighting com Quick Start page 17 Issue 1 0 6 Menu Tree Structure ...
Страница 98: ...www adblighting com Quick Start page 32 Issue 1 0 Personal Notes ...
Страница 99: ......
Страница 101: ...User Manual V 1 1 EURODIM Twin Tech M 3213 1106 53 213 Lighting Technologies ...
Страница 102: ......
Страница 161: ...EURODIM TWIN TECH www adblighting com User Manual Page 59 Issue 1 1 39 1 Errors List Screen Page Warning message ...
Страница 165: ......