Information displayed for each circuit, according to the module type:
Thyristor (per circuit)
Sinewave: always "
N/A
"
Thyristor with Diag:
1 - Displays "
OK
" if everything is fine
2 - Displays "
Damaged
": if a voltage > 210 V is measured whereas the
control measured by the module is < 25 %
Breaker (per circuit)
Sinewave:
1 - Displays "
N/A
" if the control value is < 17 % or the circuit is
overloaded or short-circuited
2 - Displays "
OK
" if the control value is > 17 % and not overloaded or
short-circuited
3 - Displays "
triggered
" if the control value is control > 17 % and no
output voltage is measured on the circuit
Thyristor (per circuit):
1 - Displays "
OK
" if the breaker is engaged
2 - Displays "
disengaged
" if the breaker has blown
Load (per circuit)
Sinewave & Thyristor with diag:
1 - Displays "
N/A
":
The control is set to zero
and/or the output voltage is too low
2 - Displays "
NO
":
If the control value is > 0
The output voltage is measured
and the current is not measured
3 - Displays "
YES
"
If the control is present
And the output voltage and the output current is measured
Overloads
(per circuit)
Sinewave:
1 - Displays "
light
": if the voltage is > 13 A for 30 secs
2 - Displays "
medium
": if the current is > 16 A for 10 secs
Here, the control decreases every 500 ms until the current
reaches < 13 A
3 - Displays "
Severe
": if the current is > 20 A for 1 sec
The control is automatically set to zero
After 2 mins, an actual control test is repeated and if the overload
is "severe" again, a second test is conducted. If the overload is
still
severe
, a status message is displayed at the bottom of the
screen, requesting the user to set all the DMX/ARTNET inputs of
the circuit to zero for 30 secs.
Thyristor with diag.:
1 -
Displays “
N/A
” if the breaker has blown
2 - Displays "
YES
” if the breaker is OK and:
If the load is > 3.5KW (for a 3kW module)
if the load > 5.5.5KW (for a 5kW module)
if the load is > 11KW (for a 10kW module)
3 - Displays "
NO
" in all other cases
Содержание EURODIM TWIN TECH
Страница 1: ...Installation Manual V 1 2 EURODIM Twin Tech M 3213 1106 03 213 Lighting Technologies ...
Страница 2: ......
Страница 6: ...EURODIM TWIN TECH www adblighting com Installation manual Page 4 Version 1 2 2 DESCRIPTION ...
Страница 48: ...EURODIM TWIN TECH www adblighting com Installation manual Page 46 Version 1 2 11 6 10 kW Module Connection ...
Страница 61: ...EURODIM TWIN TECH www adblighting com Installation manual Page 59 Version 1 2 Notes ...
Страница 62: ...EURODIM TWIN TECH www adblighting com Installation manual Page 60 Version 1 2 Notes ...
Страница 63: ......
Страница 65: ...EURODIM Twin Tech SF 3213 1106 03 213 Lighting Technologies Quick Start Guide Issue 1 0 ...
Страница 66: ......
Страница 83: ...www adblighting com Quick Start page 17 Issue 1 0 6 Menu Tree Structure ...