EURODIM TWIN TECH
www.adblighting.com
User Manual - Page 15
Issue 1.1
Hardware/communication:
"OK" if the controller is operating correctly,
"Not OK" if a problem is detected. In this case, an error message and an exclamation
mark appear in the EURODIM TT INFO zone.
Software version: software version present in the controller
Temperature:
"OK" if the temperature measured in the controller is acceptable,
"Not OK" if the temperature measured in the controller is too much high. In this case,
the control value of all of the active circuits is reduced by 1% every minute until the
temperature measured becomes again acceptable* (also see paragraph on the
operation of the ventilation within the cabinet).
12.2 EURODIM Twin Tech Information
The first row of information available informs the user via a message that the cabinet and the
modules are in operation.
The message: "reference modules are used for dimming" indicates that all the modules installed in
the cabinet are identified by the software and enable the cabinet to operate normally.
An error message may be displayed instead.
In this case, press the exclamation mark to display a screen page, "Error list".
R, S, T phase: "OK" or "Not OK", checking the presence of the mains phases at the
controller,
Fan 1, 2, 3: "OK" or "not OK", checking the rotation of each fan arranged in the top of the
cabinet and ensuring air extraction,
Software version: software version present in the Human-Machine interface (TTD HUMAN
INTERFACE (HMI)) Unit.
When any problem is detected by the cabinet. An exclamation mark then appears to the right of the
screen page. In this case, press the exclamation mark to display a screen page, "Error list".
12.3 DMX Information
DMX A/B start address DMX A, DMX B channel value to address cabinet output 1
"x": 1 ≤ x ≤ 512
"not used": channel value = 0 or > 512
"- - - - -": no circuit physically present in cabinet location 1, or circuit identification error
in cabinet location 1 or operating fault.
DMX A/B present: Yes;
Yes: DMX signal reception detected
No: DMX signal reception missing.
Patch A/B (see "PATCH" menu):
Yes: the addressing filled-in in each patch at the circuits is not in ascending order,
No: the addressing filled-in in each patch at the circuits is in ascending order,
e.g. 1, 2, 3, 4, ..., 128 where 32 modules of four circuits are present in the cabinet.
* The maximum ambient temperatures are defined in EURODIM Twin Tech data sheet.
Содержание EURODIM TWIN TECH
Страница 1: ...Installation Manual V 1 2 EURODIM Twin Tech M 3213 1106 03 213 Lighting Technologies ...
Страница 2: ......
Страница 6: ...EURODIM TWIN TECH www adblighting com Installation manual Page 4 Version 1 2 2 DESCRIPTION ...
Страница 48: ...EURODIM TWIN TECH www adblighting com Installation manual Page 46 Version 1 2 11 6 10 kW Module Connection ...
Страница 61: ...EURODIM TWIN TECH www adblighting com Installation manual Page 59 Version 1 2 Notes ...
Страница 62: ...EURODIM TWIN TECH www adblighting com Installation manual Page 60 Version 1 2 Notes ...
Страница 63: ......
Страница 65: ...EURODIM Twin Tech SF 3213 1106 03 213 Lighting Technologies Quick Start Guide Issue 1 0 ...
Страница 66: ......
Страница 83: ...www adblighting com Quick Start page 17 Issue 1 0 6 Menu Tree Structure ...
Страница 98: ...www adblighting com Quick Start page 32 Issue 1 0 Personal Notes ...
Страница 99: ......
Страница 101: ...User Manual V 1 1 EURODIM Twin Tech M 3213 1106 53 213 Lighting Technologies ...
Страница 102: ......
Страница 161: ...EURODIM TWIN TECH www adblighting com User Manual Page 59 Issue 1 1 39 1 Errors List Screen Page Warning message ...
Страница 165: ......