3. INSTALLATION
3.1 Dimmer room
3.1.1
Preparation
Determine the dimensions of the dimmer room so as to place all EURODIM Twin Tech
cabinets easily. Provide for an open space of approximately 90 cm in front of the cabinets to
facilitate maintenance. Before attempting to move the rack(s) into the final position, check
access routes to the dimmer room for space to manoeuvre through doorways and around
corridor corners. The cabinets can be placed against a wall, side by side or back to back.
The supply cables and the load cables can enter the wiring compartment either from the top
or bottom of the cabinet. See drawing for size and location of cable entries.
Dimmer Room Requirements
A clean (not dusty) temperature-controlled environment.
Restricted public access to prevent any unauthorised tampering with the
dimmer settings.
Soundproofing or performance area separation to muffle ventilation fan noise.
Acoustic measurements are available from ADB Lighting Technologies.
Provide for a free space, minimum 30 cm above the EURODIM Twin Tech so
as to facilitate the exhaust airflow.
If an optional “Silencer” is used, then more
space may be necessary. The dimensions and weight of the cabinets are
included in the Chapter
“Characteristics”. Plan for fire extinguishers in
compliance with local regulations. The lighting of the area should be sufficient
for maintenance and inspection. A level of 300 lux is considered satisfactory.
Plan for mains outlets in the room, independent of the supply of the dimmers.
Plan for an Ethernet network to the control room an
d a cable for remote “CPU1 - CPU2”
selection (if applicable).
EURODIM Twin Tech cabinets are professional equipment and relevant safety rules are
applicable. EURODIM Twin Tech cabinets should be placed in areas that are accessible only
to persons responsible for maintenance, surveillance or repair of the equipment.
Please refer to local regulations and requirements.
Such an area should be located as close as possible to the stage or studio, in order to
reduce the length of the electrical cables, and therefore, the cost of installation. At the time of
installation of the cabinets in the area, it should be completely unobstructed; that is, that all
engineering work, wall or floor covering work, painting, electric lighting work, drilling, welding,
etc., must be completed.
Do not install the plug-in modules until all wiring installation is completed.
EURODIM Twin Tech has been designed to European standards for electrical switchgear
EN60439. It is CE marked. See chapter 11.10 CE Declaration Document for EURODIM Twin
Tech.
Содержание EURODIM TWIN TECH
Страница 1: ...Installation Manual V 1 2 EURODIM Twin Tech M 3213 1106 03 213 Lighting Technologies ...
Страница 2: ......
Страница 6: ...EURODIM TWIN TECH www adblighting com Installation manual Page 4 Version 1 2 2 DESCRIPTION ...
Страница 48: ...EURODIM TWIN TECH www adblighting com Installation manual Page 46 Version 1 2 11 6 10 kW Module Connection ...
Страница 61: ...EURODIM TWIN TECH www adblighting com Installation manual Page 59 Version 1 2 Notes ...
Страница 62: ...EURODIM TWIN TECH www adblighting com Installation manual Page 60 Version 1 2 Notes ...
Страница 63: ......
Страница 65: ...EURODIM Twin Tech SF 3213 1106 03 213 Lighting Technologies Quick Start Guide Issue 1 0 ...
Страница 66: ......
Страница 83: ...www adblighting com Quick Start page 17 Issue 1 0 6 Menu Tree Structure ...
Страница 98: ...www adblighting com Quick Start page 32 Issue 1 0 Personal Notes ...
Страница 99: ......
Страница 101: ...User Manual V 1 1 EURODIM Twin Tech M 3213 1106 53 213 Lighting Technologies ...
Страница 102: ......
Страница 161: ...EURODIM TWIN TECH www adblighting com User Manual Page 59 Issue 1 1 39 1 Errors List Screen Page Warning message ...
Страница 165: ......