7.2 AVR6000 BACnet Points List
BACnet Points List is Continued on the Next Page
DESCRIPTION
PV
UNITS
Device Object
-
Supply Airflow Volume
R
Flow Volume
Supply Valve Feedback Position
R
%
General Exhaust Airflow Volume
R
Flow Volume
Room Temperature
R
Temperature
Flash Writes Remaining
(Ref Note 1)
R
Integer
Discharge Air Temperature
R
Temperature
Discharge Air Temperature Set Point
R
Temperature
Total Exhaust Airflow Volume
R
Flow Volume
Minimum Exhaust Airflow Volume Set Point
R
Flow Volume
Minimum Supply Airflow Volume Set Point W/DMC
R
Flow Volume
Additional Exhaust Airflow Volume
R
Flow Volume
Room Offset Airflow Volume
R
Flow Volume
Air Changes Per Hour
R
Integer
--
--
--
Total Supply Airflow Volume
R
Flow Volume
Active Mode Min Supply Airflow Set Point
R
Flow Volume
Active Mode Max Heating Supply Airflow Set Point
R
Flow Volume
Active Mode Max Supply Airflow Set Point
R
Flow Volume
Active Mode Max General Exhaust Airflow Set Point
R
Flow Volume
Active Mode Room Offset Airflow Set Point
R
Flow Volume
Active Mode Min General Exhaust Airflow Set Point
R
Flow Volume
Active Mode Supply Airflow CAV Set Point
R
Flow Volume
Active Mode Room Temperature Heating Set Point
R
Temperature
Active Mode Room Temperature Cooling Set Point
R
Temperature
Active Mode Min Discharge Temperature Set Point
R
Temperature
Active Mode Max Discharge Temperature Set Point
R
Temperature
Active Mode General Exhaust Airflow CAV Set Point
R
Flow Volume
Analog Setpoint Values (Ref Note 2)
Mode
1
Mode
2
Mode
3
Mode
4
Min Supply Airflow Set Point
AV101 AV201 AV301 AV401 R/W Flow Volume
Max Heating Supply Airflow Set Point
AV102 AV202 AV302 AV402 R/W Flow Volume
Max Supply Airflow Set Point
AV103 AV203 AV303 AV403 R/W Flow Volume
Max General Exhaust Airflow Set Point
AV104 AV204 AV304 AV404 R/W Flow Volume
Room Offset Airflow Set Point
AV105 AV205 AV305 AV405 R/W Flow Volume
Min General Exhaust Airflow Set Point
AV106 AV206 AV306 AV406 R/W Flow Volume
Supply Airflow CAV Setpoint
AV107 AV207 AV307 AV407 R/W Flow Volume
Room Temperature Heating Set Point
AV108 AV208 AV308 AV408 R/W Temperature
Room Temperature Cooling Set Point
AV109 AV209 AV309 AV409 R/W Temperature
Min Discharge Air Temperature Set Point
AV110 AV210 AV310 AV410 R/W Temperature
Max Discharge Air Temperature Set Point
AV111 AV211 AV311 AV411 R/W Temperature
General Exhaust Airflow CAV Set Point
AV112 AV212 AV312 AV412 R/W Flow Volume
Analog Values
AI4
AI5
AI6
AI7
AI8
AI12
AI13
--
DExxx
AI1
AI2
AI3
Analog Inputs
AV9
AV10
AV12
OBJECT ID
AV2
AV3
AV4
AV5
AV8
AI9
AI10
AI11
AI15
AV1
AV6
AV7
AV11