INSTALLATION
STEP 1
Remove the two middle panel brackets.
STEP 2
Remove the top brick panel.
STEP 3
Slightly loosen the two button head screws and adjust the restrictor as shown.
OPEN
CLOSED
Button Head Screws
Restrictor Adjustment
Adjust the restrictor to achieve the desired flame appearance on any top venting configuration with 6 ft (1.83 m) of vertical
pipe or more. Vertical terminations may display an active, compact flame. If this appearance is not desirable, the restrictor
may need to be adjusted. Allow 15 minutes of burn time before making any adjustments. Adjust the restrictor as shown in this
manual.
Restrictor Adjustment Guidelines
Flame Appearance
Draft Problem
Solution
Short, flickering
Excessive draft or not enough
restriction
Adjust restrictor plate to close more
Lifting or ghosting*
Insufficient draft
Adjust restrictor plate to open more
*If flames continue to lift or ghost after opening the restrictor and verifying correct vent installation, shut off the gas supply
and call a qualified service technician.
Steps one and two are only required if adjustments to the restrictor are needed after the appliance has been
installed.
To avoid property damage or personal injury, allow ample time to cool before making any adjustments.
Improper vent installation may cause the burner flames to lift or “ghost.” Perform a visual check on flame appearance after
restrictor adjustment to ensure proper performance.
TOP VENT (VERTICAL ONLY)