19
INSTALLATION
GAS LINE CONNECTION
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at pressures in excess of ½ psi (3.5 kPa). For test pressures equal to or less than ½ psi
(3.5 kPa), the appliance must be isolated from the gas supply piping system by closing its individual manual shut-off
valve.
The conversion shall be carried out in accordance with the requirements of the provincial authorities
having jurisdiction and in accordance with the requirements of the ANSI Z223.1 installation code.
Gas Conversion (sold separately)
This appliance is manufactured for use with natural gas. Follow the instructions included with the conversion kit if converting
to LP gas. The conversion kit shall be installed by a qualified service agency.
Gas Line Installation
A listed (and Commonwealth of Massachusetts approved) ½ in. (13 mm) tee handle manual shut-off valve and flexible gas
connector are to be connected to the ½ in. (13 mm) control valve inlet. If substituting for these components, please consult
local codes for compliance.
•
This appliance is equipped with a ⅜” (10 mm) x 18” (457 mm) long flexible gas connector and manual shut-off valve.
•
Run gas line into appliance. The gas line should be run to the point of connection where the shut-off valve and flexible
gas line will connect.
• Do not run gas line in a manner that would obstruct fan operation.
• For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating methods.
Inlet Gas Supply Pressures
Fuel
Minimum Pressure
Maximum Pressure
Natural Gas
5” WC (1.25 kPa)
10.5” WC (2.62 kPa)
LP Gas
12” WC (2.674 kPa)
14” WC (3.49 kPa)
Installation of the gas line must only be done by a qualified person in accordance with local
building codes, if any. If not, follow ANSI 223.1. Commonwealth of Massachusetts installations
must be done by a licensed plumber or gas fitter.
IMPORTANT