10
Gas Pressures
Natural Propane (LP)
Inlet Minimum
5.0" w.c.
12.0" w.c.
Inlet Maximum
10.5" w.c.
14.0" w.c.
Manifold Pressure 3.8" w.c.
11.0" w.c.
Gas Specifications & Orifice Size
Fuel Max. Input
BTU/h
Min. Input
BTU/h
Orifice
Size
Nat.
27,000
14,000
#40
LP
27,000
13,000
#53
High Elevations
Input ratings are shown in BTU per hour and are certified without derating for elevations up to 4,500 feet (1,370 m) above sea
level.
For elevations above 2,000 feet (50.8 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/
or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet
(1,370 m). Natural Gas and Propane Installation Code, CSA B149.1
OVERVIEW
If you live in a cold climate, seal all cracks around your appliance, and wherever cold air could enter the room,
with noncombustible material. It is especially important to insulate the outside chase cavity between the studs and
under the floor on which the appliance rests, if the floor is above ground level.
Failure to follow these instructions will void the warranty.
This appliance must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate
solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems.
Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury,
property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious
injury, property damage or loss of life.
Do not pack the open air spaces with insulation or other materials. This could cause high temperatures and may present
a fire hazard and serious injury, property damage or loss of life. Operation of improperly installed and maintained venting
system could result in serious injury, property damage or loss of life.
PART OVERVIEW
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and
immediately inform your authorized dealer if any damage is found. Do not install any damaged, incomplete, or substitute
parts. Check your packing list to verify that all listed parts have been received.