16
Floor Support And Protection
•
If installed directly on carpeting, tile, or other combustible material other than wood flooring, this appliance shall be
installed on a metal or wood panel extending the full width and depth of the appliance.
•
If installed above floor level, a solid, continuous platform must be constructed below the appliance.
•
Consider the height of hearth finish material (stone, brick, etc.) when building a platform. The bottom of the appliance
must be level with finished hearth to allow for a proper fit of the safety barriers.
• Build the hearth to desired size and height. If a hearth extension is desired, combustible material may be used.
Vent Termination Framing
15-7/8”
(403mm)
39”
(991mm)
Top Vent Minimum
Horizontal Venting
INSTALLATION
FIRE HAZARD: Do NOT install directly on carpeting, vinyl, or any other combustible material other than wood.
DO NOT RECESS THE VENT CAP INTO WALL OR SIDING.
Vertical Terminations
• Follow vent pipe manufacturer’s installation instructions for vertical terminations.
• A minimum of 1 in (25 mm) clearance on all sides of the vertical vent pipe must be maintained.
• Attic insulation shields may be insulated using unfaced insulation products listed as non-combustible per ASTM E 136.
Cold air transfer area. The surround appliance chase must comply with all clearances as
outlined in this manual, and be constructed in compliance with local building codes. Outside
walls should be insulated to prevent cold air from entering room.
Vent cap location must be in compliance with the minimum termination clearance information listed in
this manual.