15
Approved vent system elbows vary in vertical length. Consult vent manufacturer’s instructions to determine the
elbow dimension used for your installation. Adjust as necessary to maintain the required 1” (25mm) clearance from
the vent pipe to combustible material.
INSTALLATION
TYPICAL HORIZONTAL INSTALLATION
TOP VENT
36
¼
”
(920mm)
1”
(25mm)
15 ”
(403mm)*
TYPICAL HORIZONTAL INSTALLATION
REAR VENT
1”
(25mm)
36
¼
”
(920mm)
15 ”
(403mm)*
TYPICAL VERTICAL INSTALLATION
TOP VENT
”
1”
(25mm)
36
¼
”
(920mm)
15
(403mm)*
TYPICAL CORNER INSTALLATION
TOP VENT
50 ”
(1280mm)
36
¼
”
(920mm)
11 ”
(301mm)
¼
”
(6mm)
24
”
(628mm)
35 ”
(905mm)
TYPICAL VERTICAL INSTALLATION
REAR VENT
26
½
”
(673mm)**
1”
(25mm)
36
¼
”
(920mm)
Minimum Clearances to Combustible Material
From Appliance To
inches
mm
Top Stand-Offs
0
0
Left And Right Side Stand-Offs
0
0
Back Stand-Offs
0
0
Corners
1/4
6
Front
36
915
Top To Ceiling
51
1295
Sides To Adjacent Sidewall
6
153
Mantel 9 in (229 mm) deep, 10” (254 mm) from appliance top
**DIMENSION SHOWN WITH LISTED DURAVENT ELBOW.
**UNITS SHOWN WITHOUT HEAT SHIELD FOR CLARITY.
Apply a generous amount of high temperature sealant to the around
the flue outlet.
IMPORTANT