150
November, 2018 Rev.1.4
The next figure shows flow chart for handling slave transmitter function of I
2
C.
SLA+R
ACK
DATA
LOST&
S or Sr
Y
0x47
ACK
STOP
Y
N
0x46
P
0x22
IDLE
IDLE
Y
GCALL
0x1F
0x97
0x17
From master to slave /
Master command or Data Write
From slave to master
0xxx
Value of Status Register
ACK
Interrupt
, SCL line is held low
Interrupt
after stop command
P
Arbitration lost as master and
addressed as slave
LOST&
General Call Address
GCALL
Figure 11-53 Formats and States in the Slave Transmitter Mode
Содержание MC96FR364B
Страница 17: ...MC96FR364B November 2018 Rev 1 4 17 4 PACKAGE DIMENSION...
Страница 18: ...MC96FR364B 18 November 2018 Rev 1 4 Figure 4 1 PKG DIMENSION 28 TSSOP...
Страница 23: ...MC96FR364B November 2018 Rev 1 4 23 6 3 REMOUT Port Data PAD VDD Figure 6 3 REMOUT port...
Страница 69: ...November 2018 Rev 1 4 69 Initial value 00H BIT 7 0 BIT counter value...