7.19 Replacement of Choke Filter
7.19 Replacement of Choke Filter
Location
The Choke Filter is used if the controller is equipped with ‘high voltage’ drive
system (IRB 5500). The filter (if used) is connected between the power relay and
the rectifier AC power inlet. The filter is located beside the transformer on the rear
side of the controller as shown below.
Figure 84 Transformer
References
– For information on the choke filter, see ‘Unit Description, IRC5P’
Tools and Items
– Hand tools
Removal
The procedure describes how to remove the choke filter unit.
WARNING!
No repair work must be performed on the robot before the safety
on page 13 have been read and understood.
1.
Turn the electrical disconnect switch ‘off’ and lock switch in ‘off’ position.
WARNING!
Make sure that the mains switch is ‘off’ and locked in ‘off’ position
before continuing. Also make sure that possible other connected systems are ‘off’.
2.
Remove control cabinet rear housing (
/2).
1
Choke filter (on rear side)
2
Cabinet rear housing
3
Choke filter connections
4
Choke filter attachment screws
1
3
Rear view
4
1
2
Содержание IRC5P
Страница 1: ...The heart of Robotics Product Manual Control Cabinet IRC5P 3HNA009834 001 en Rev 06 ...
Страница 2: ......
Страница 10: ...10 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P ...
Страница 14: ...2 Safety 14 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P ...
Страница 30: ...3 System Description 3 4 Pendant Description 30 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P ...
Страница 218: ...218 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P Manual Status ...