5 Installation and Commissioning
Product Manual, Control Cabinet IRC5P
113
5.7 Misc. System Connections
3.
Enter flexible hose into the right inlet on the purge unit for the single cable
version. For the dual cable version, enter motor cable in right inlet and signal
cable in the second inlet from the right as shown in
(the signal cable
is the cable which includes screened cables).
4.
Check that gasket(s) for the cable attachment is properly positioned and secure
cable flange(s) with 4 screws.
5.
Route purge sensor cable and connector to hole on top of the purge unit
connection box. Enter connector through hole and secure with 4 screws.
6.
Insert connectors from flexible hose(s) in receptacles for cables from control
cabinet according to markings on connectors and
7.
The screened cables include a p-clip at a stripped-off section of the cable
insulation. Secure these p-clips to the ground rail as shown in
.
8.
Secure loose wires using Panduit strips. Check that the wires are properly
secured so that they will not apply strain to the connectors.
9.
Connect ground wire from manipulator to ground rail (not used on all versions).
10. Make sure that the gasket for the purge unit cover is properly positioned, install
cover and tighten attachment screws. Make sure that all screws are in place to
prevent air leakage.
Содержание IRC5P
Страница 1: ...The heart of Robotics Product Manual Control Cabinet IRC5P 3HNA009834 001 en Rev 06 ...
Страница 2: ......
Страница 10: ...10 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P ...
Страница 14: ...2 Safety 14 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P ...
Страница 30: ...3 System Description 3 4 Pendant Description 30 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P ...
Страница 218: ...218 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P Manual Status ...